This provision will coincide with the seat area design of most examination chairs. NPRM Proposed Provision: M302.2.3 Transfer Sides....
Search Results "Day Use Area"
-
5.3.3 Transfer Sides Recommendations for M302
-
A. Responsibilities of All State Agency Recipients
example, a State agency must ensure compliance with Section IV of these Guidelines if and when it reviews a vocational education agency decision to create or change a geographic service area...
-
Are self-evaluations and transition plans required to be updated?
The current (2010) ADA Standards have design requirements for swimming pools, play areas, fishing piers, golf courses, accessible routes to ball fields and more....
-
Wheelchair Spaces
The 33-inch minimum width for spaces provides extra width for maneuvering within a confined area....
-
2. a. ii. Responsibility
Allocations of responsibilities between landlord and tenant for removing barriers when readily achievable, and modifying policies, both in common areas as well as within places of public...
-
F248.1 General
Removable beach access routes can be moved to a protected storage area during storms and other periods when the routes are subject to damage or loss....
-
1016.1 General
At viewing areas, when an entity determines that a condition in 1019 does not permit full compliance on a portion of an outdoor recreation access route with a specific provision in 1016,...
-
604.5.2 Rear Wall
valves to be located in a position that conflicts with the location of the rear grab bar, then the rear grab bar shall be permitted to be split or shifted to the open side of the toilet area...
-
1. Snow and Ice
conditions at a bus stop make it difficult or impossible for a fixed route passenger with a disability to get to a lift, or for the lift to deploy, the driver should move the bus to a cleared area...
-
11B-405.9 Edge protection
Edge protection shall not be required on the sides of ramp landings having a vertical drop-off of ½ inch (12.7 mm) maximum within 10 inches (254 mm) horizontally of the minimum landing area...
-
11B-213.3.6 Bathing facilities
Where two or more accessible showers are provided within the same functional area, at least one shower shall be opposite hand from the other or others (that is, one left-hand controls versus...
-
11B-405.9 Edge protection
Edge protection shall not be required on the sides of ramp landings having a vertical drop-off of ½ inch (12.7 mm) maximum within 10 inches (254 mm) horizontally of the minimum landing area...
-
11B-1009.3.3 Handrails
Where a sloped entry is provided for wave action pools, leisure rivers, sand bottom pools, and other pools where user access is limited to one area, the handrails shall not be required to...
-
604.5.2 Rear Wall
valves to be located in a position that conflicts with the location of the rear grab bar, then the rear grab bar shall be permitted to be split or shifted to the open side of the toilet area...
-
1009.3.3 Handrails
Where a sloped entry is provided for wave action pools, leisure rivers, sand bottom pools, and other pools where user access is limited to one area, the handrails shall not be required to...
-
1009.3.3 Handrails
Where a sloped entry is provided for wave action pools, leisure rivers, sand bottom pools, and other pools where user access is limited to one area, the handrails shall not be required to...
-
M301.4 Lift Compatibility
Diagnostic equipment shall be usable with portable patient lifts and, when in use with such lifts, shall comply with M301.4.1 or M301.4.2....
-
M302.4 Lift Compatibility
Diagnostic equipment shall be usable with portable patient lifts and, when in use with such lifts, shall comply with M302.4.1 or M302.4.2. ...
-
Basic Features
Basic Features Inmates with disabilities - including those who use wheelchairs - need to be able to enter their cells and move around inside them, using the cells’ features without assistance...
-
M101.7 Units of Measurement (Section-by-Section Analysis)
In the MDE NPRM there was no explanation of the units of measurement used throughout the rule text....
-
2. Roll-in Shower Size
If there are more than 50 guestrooms/suites, are all required roll-in showers at least 30" wide by 60" long or 36" wide by 60", as configured in Figure 57 below, so persons who use wheelchairs...
-
7(2)(a)(i)
(i) Sufficient maneuvering space is provided within the bathroom for a person using a wheelchair or other mobility aid to enter and close the door, use the fixtures, reopen the door and...
-
Entrance
As used in the Guidelines, "entrance" refers to an exterior entry door....
-
12113(c) Qualification standards and tests related to uncorrected vision
.— Notwithstanding section 12102(4)(E)(ii), a covered entity shall not use qualification standards, employment tests, or other selection criteria based on an individual’s uncorrected vision...