exception; there are no accessibility requirements for the area of work on the roof.2 Roof mounted PV systems are not considered alteration projects that would trigger path of travel...
Search Results "Travel Distance"
-
3. Roof Mounted PV Systems
-
11B-405.2 Slope
To accommodate the widest range of users, provide ramps with the least possible running slope and, wherever possible, accompany ramps with stairs for use by those individuals for whom distance...
-
11B-405.2 Slope
To accommodate the widest range of users, provide ramps with the least possible running slope and, wherever possible, accompany ramps with stairs for use by those individuals for whom distance...
-
2.1 Parking
If it is a long distance, is there an accessible and available motorized cart, van or bus?...
-
2 Method
The two main dependent measures were: Whether the detectable warnings could be seen from distances between 2.44 m (8ft) and 7.92 m (26 ft)....
-
11B-705.1.2.7 Track crossings
Detectable warnings at track crossings shall be 36 inches (914 mm) in the direction of pedestrian travel and extend the full width of the circulation path....
-
11B-505.2.1 Orientation
Adds requirement that at least one handrail must be in direction of travel, perpendicular to the stair nosing....
-
§ 37.125(h)(3)(i)
(i) In applications for ADA paratransit eligibility, the entity may require the applicant to indicate whether or not he or she travels with a personal care attendant....
-
11B-705.1.2.7 Track crossings
Detectable warnings at track crossings shall be 36 inches (914 mm) in the direction of pedestrian travel and extend the full width of the circulation path....
-
§382.117(a)(1)
(1) You must not deny transportation to a service animal on the basis that its carriage may offend or annoy carrier personnel or persons traveling on the aircraft....
-
§382.29(a)
(a) Except as provided in paragraph (b) of this section, you must not require that a passenger with a disability travel with another person as a condition of being provided air transportation...
-
Circulation Path
An exterior or interior way of passage provided for pedestrian travel, including but not limited to, walks, hallways, courtyards, elevators, platform lifts, ramps, stairways, and landings...
-
106.5.19 Circulation Path
An exterior or interior way of passage provided for pedestrian travel, including but not limited to, walks, hallways, courtyards, elevators, platform lifts, ramps, stairways, and landings...
-
11B-806.2.4 Toilet and bathing facilities
Toilet and bathing fixtures required to comply with Sections 11B-603 through 11B-610 shall be permitted to be located in more than one toilet or bathing area, provided that travel between...
-
11B-806.2.4 Toilet and bathing facilities
Toilet and bathing fixtures required to comply with Sections 11B-603 through 11B-610 shall be permitted to be located in more than one toilet or bathing area, provided that travel between...
-
11B-806.2.4 Toilet and bathing facilities
Toilet and bathing fixtures required to comply with Sections 11B-603 through 11B-610 shall be permitted to be located in more than one toilet or bathing area, provided that travel between...
-
11B-1009.5.4 Transfer steps
Where possible, the height of the transfer step should be minimized to decrease the distance an individual is required to lift up or move down to reach the next step to gain access....
-
Gripping Surface Cross Section and Clearances M301, M302, and M305.2
The transfer supports shall be located at a maximum distance from transfer surface of 1 ½ inches....
-
704.8.2 First story
In occupancies other than Group H, unlimited unprotected openings are permitted in the first story of exterior walls facing a street that have a fire separation distance of greater than...
-
1009.5.4 Transfer Steps
Where possible, the height of the transfer step should be minimized to decrease the distance an individual is required to lift up or move down to reach the next step to gain access....
-
4.25.3 Height
Where the distance from the wheelchair to the clothes rod or shelf exceeds 10 in (255 mm) (as in closets without accessible doors) the height and depth to the rod or shelf shall comply with...
-
Width [4.3.3.] and Passing Space [4.3.4]
A continuous minimum clear width of 36 inches is required for accessible routes, but a reduction to 32 inches is allowed for a linear distance of no more than 24 inches (e.g., a doorway)...
-
4.9.4(2)
At the bottom, the handrail shall continue to slope for a distance of the width of one tread from the bottom riser; the remainder of the extension shall be horizontal (see Fig. 19(c) and...