Section 35.151(i) Curb ramps
- SafePath VulcanLanding™ Rubber Transition Ramp
-
11B-406.5.3 Landings
The slope of the landing in all directions shall be 1:48 maximum. [2010 ADA Standards] 406.4 Landings. Landings shall be provided at the tops of curb ramps....
-
11B-504.5 Nosings
Risers shall be permitted to slope under the tread at an angle of 30 degrees maximum from vertical....
-
Thresholds: ADA Standard Section 404.2.5
Section 404.2.5 covers the current ADA Standards for thresholds at doors.
-
11B-403.6 Handrails
Where handrails are provided along walking surfaces with running slopes not steeper than 1:20 they shall comply with Section 11B-505. Advisory 11B-403.6 Handrails....
-
R204.2 Sidewalks
alighting areas and boarding platforms at transit stops (see R213 and R308.1.3.2), transit shelters (see R213 and R308.2), accessible on-street parking spaces (see R214 and R309), parking meters...
-
Data Analyses
Thus, the energy consumption for each surface (oxygen consumption/kilogram of body weight/meter) was standardized relative to subject size (body weight), resting metabolic levels and speed...
-
Wading pools. (Section-by-Section Analysis)
Section 242.3 of the 2004 ADAAG provides that newly constructed or altered wading pools must provide at least one sloped means of entry to the deepest part of the pool. ...
-
Transfer Space: ADA Standard Section 1009.5.2
A transfer space of 60 inches (1525 mm) minimum by 60 inches (1525 mm) minimum with a slope not steeper than 1:48 shall be provided at the base of the transfer platform surface and shall...
-
11B-1009.5.2 Transfer space
A transfer space of 60 inches (1524 mm) minimum by 60 inches (1524 mm) minimum with a slope not steeper than 1:48 shall be provided at the base of the transfer platform surface and shall...
-
RAMP
A walking surface that has a running slope steeper than one unit vertical in 20 units horizontal (5-percent slope)....
-
RAMP
A walking surface that has a running slope steeper than one unit vertical in 20 units horizontal (5-percent slope)....
-
RAMP
A walking surface that has a running slope steeper than one unit vertical in 20 units horizontal (5-percent slope)....
- American Standard Stallbrook Urinal
-
405.4 Floor or Ground Surfaces
Changes in level other than the running slope and cross slope are not permitted on ramp runs....
-
405.4 Floor or Ground Surfaces
Changes in level other than the running slope and cross slope are not permitted on ramp runs....
-
11B-405.4 Floor or ground surfaces
Changes in level other than the running slope and cross slope are not permitted on ramp runs....
-
Blended Transitions (R304.4) (Section-by-Section Analysis)
Blended Transitions (R304.4) (Section-by-Section Analysis) A maximum running slope of 5 percent is specified for blended transitions....
-
11B-405.4 Floor or ground surfaces
Changes in level other than the running slope and cross slope are not permitted on ramp runs....
-
11B-405.4 Floor or ground surfaces
Changes in level other than the running slope and cross slope are not permitted on ramp runs....
-
R202.3.3 Reduction in Access Prohibited
Sidewalk improvements that correct existing excessive cross slope should be carefully planned to avoid creating excessive slope in curb ramps or adding a step at existing building entrances...
-
11B-406.3 Parallel curb ramps
A parallel curb ramp may be provided with one sloping segment or two opposing sloping segments....
-
Nosings: ADA Standard Section 504.5
Section 504.5 covers the current ADA Standards for stair nosings.