Because the user does not normally need to push, these scooters often have a platform wide enough for two adult feet side by side....
Search Results "Push Button"
Commonly Searched Documents
-
Motorized Kick Scooters
-
1132A.9 Smooth surface
Swinging door or gate surfaces within 10 inches (254 mm) of the finish floor or ground measured vertically shall have a smooth surface on the push side extending the full width of the door...
-
1132A.9 Smooth surface
Swinging door or gate surfaces within 10 inches (254 mm) of the finish floor or ground measured vertically shall have a smooth surface on the push side extending the full width of the door...
- Cal-Royal Legacy Series Locksets
- Otis Elevator HANDSOFF Phone
- Georgia-Pacific enMotion® Automated Touchless Soap Dispenser
- United Cerebral Palsy (UCP)
-
11B-407.4.7.2 Keypads
Keypads shall be identified by characters complying with Section 11B-703.5 _|Signs; Visual Characters|_ and shall be centered on the corresponding keypad button....
-
407.2.2.1 Visible and Audible Signals
Where in-car signals are provided, they shall be visible from the floor area adjacent to the hall call buttons. EXCEPTIONS: 1....
-
407.2.2.1 Visible and Audible Signals
Where in-car signals are provided, they shall be visible from the floor area adjacent to the hall call buttons. EXCEPTIONS: 1....
-
v. Infusion pumps
Infusion pumps often rely on patients controlling settings on difficult-to-reach buttons or flat screens that may not be accessible to individuals with disabilities....
-
FAQ: How do I create a WorkGroup in Corada?
Click the "Save WorkGroup" button. Note: This feature is available to Premium- and Accessibility Specialist-level subscribers only. Need to upgrade your subscription? Click here!...
-
Two-Way Communication Systems [§230 and §708]
Control buttons and other operable parts must comply at those systems located at accessible entrances....
-
Can elevator doors close sooner than the minimum opening time specified when users activate door close?
automatic operation) cannot reduce the initial opening time of doors (3 seconds minimum) or the minimum door signal timing (based on 1.5/ ft/s travel speed for the distance from the hall call button...
-
11B-407.4.7.2 Keypads
Keypads shall be identified by characters complying with Section 11B-703.5 _|Signs; Visual Characters|_ and shall be centered on the corresponding keypad button....
-
2.2.6 Door Use
Trials in both directions were performed (i.e. from push and pull sides) using a forward approach. Each door presented different types of challenges to WhMD users....
-
Manual Wheelchairs
Users can propel themselves using push rims attached to the rear wheels. Braking is accomplished by resisting wheel movement with the hands or arms....
-
404.2.9 Door and Gate Opening Force
The force for pushing or pulling open a door or gate other than fire doors shall be as follows: 1. Interior hinged doors and gates: 5 pounds (22.2 N) maximum. 2....
-
Door Maneuvering Clearance
depth of this clearance is increased where a closer is provided because additional space is needed to counteract the force of closers while maneuvering through the door from either the push...
-
404.2.9 Door and Gate Opening Force
The force for pushing or pulling open a door or gate other than fire doors shall be as follows: 1. Interior hinged doors and gates: 5 pounds (22.2 N) maximum. 2....
-
1132A.9 Smooth surface
Swinging door or gate surfaces within 10 inches (254 mm) of the finish floor or ground measured vertically shall have a smooth surface on the push side extending the full width of the door...
- Steelcase Ology Series Height-Adjustable Table
- The Right to be Rescued
- Georgia-Pacific enMotion® Brushed Stainless Automated Touchless Soap Dispenser