The walking surface on steps serving all other non-rail vehicle doorways shall be lighted at all times with 2 foot-candles (22 lux) minimum of illumination.
Search Results "Pocket Door"
Commonly Searched Documents
-
T503.4 Steps at Other Doorways
-
SECTION 1004 EXIT ACCESS
SECTION 1004 EXIT ACCESS
-
A4.2.1(1) Space Requirements for Wheelchairs
(1) Space Requirements for Wheelchairs. Most wheelchair users need a 30 in (760 mm) clear opening width for doorways, gates, and the like, when the latter are entered head-on. If the...
-
A4.2.1(1) Space Requirements for Wheelchairs
(1) Space Requirements for Wheelchairs. Many persons who use wheelchairs need a 30 in (760 mm) clear opening width for doorways, gates, and the like, when the latter are entered...
-
§ 38.73 Doorways
[See subsections ...]
-
§ 38.53 Doorways
[See subsections ...]
-
1. Clear Width
Do bathroom doors in accessible guestrooms allow at least 32" of clear passage width to accommodate persons who use wheelchairs, walkers and other mobility aids?...
-
Handles, Pulls, and Knobs
Knobs that require a full hand grip and turning, including round door knobs and shower controls, do not comply because they require twisting of the wrist....
-
11B-603.2 Clearances
Clearances shall comply with Section 11B-603.2.
-
803.3 Door Swing
Doors shall not swing into the room unless a clear floor or ground space complying with 305.3 is provided beyond the arc of the door swing....
-
803.3 Door Swing
Doors shall not swing into the room unless a clear floor or ground space complying with 305.3 is provided beyond the arc of the door swing....
- Panda S.81 All Aluminum Multi-Slide Door System Corner Detail
- Panda TS.83 Thermally Broken Multi-Slide Door System Corner Detail
- Panda S.90 All Aluminum Slim Profile Multi-Slide Door System
-
T502.3.1 Clear Width
Doorways shall provide a clear opening of 32 inches (810 mm) minimum.
-
11B-813.2.10 Door swing
A door, in any position, shall be permitted to encroach into the turning space by 12 inches (305 mm) maximum....
-
1132A.5.1 General
The floor or landing on the dwelling unit side of the primary entry door and any required exit door shall have a minimum length of not less than 44 inches (1118 mm)....
-
1132A.5.1 General
The floor or landing on the dwelling unit side of the primary entry door and any required exit door shall have a minimum length of not less than 44 inches (1118 mm)....
-
603.2.3 Door Swing
603.2.3 Door Swing. Doors shall not swing into the clear floor space or clearance required for any fixture. Doors shall be permitted to swing into the required turning space....
-
Scoping [4.1.3(7)]
Scoping [4.1.3(7)] Doors required to be accessible include: at least one door at each accessible entrance at least one door at each accessible space within a building...
-
603.2.3 Door Swing
Doors shall not swing into the clear floor space or clearance required for any fixture. Doors shall be permitted to swing into the required turning space. EXCEPTIONS: 1....
-
603.2.3 Door Swing
Doors shall not swing into the clear floor space or clearance required for any fixture. Doors shall be permitted to swing into the required turning space. EXCEPTIONS: 1....
-
1010.1.5 Floor elevation
There shall be a floor or landing on each side of a door. Such floor or landing shall be at the same elevation on each side of the door....
-
1132A.4 Level floor or landing
The floor or landing on each side of a door shall be level....