Visual Notification Devices Care must be taken that notification devices intended to signal a door knock or bell are separately wired....
Search Results "Pocket Door"
Commonly Searched Documents
-
Visual Notification Devices
-
LaCantina Multi-slide Aluminum Wood Sliding Door System Pocket Door Model
Requires the Premium User plan or above. (Login or upgrade your account!)
-
D2
Does at least one door or one side of a double leaf-door provide at least 32 inches clear passage width when the door is open 90 degrees?...
-
Inventory Control Devices
Inventory Control Devices It is important that inventory control or security devices not obstruct required maneuvering clearances at doors....
-
Doorways [4.8.4]
Landings must provide the maneuvering clearance at doors required in ADAAG 4.13. ADAAG allows the landing to overlap maneuvering clearances at doors....
- Motorized Lift & Slide Door System by Panda
-
§ 38.153 Doors, steps and thresholds
[56 FR 45756, Sept. 6, 1991, as amended at 63 FR 51698, 51702, Sept. 28, 1998]
-
In-swinging Bathroom Doors
The commenter recommended that in-swinging doors be prohibited unless there is sufficient internal bathroom space, exclusive of the swing of the door, which allows either a five foot turning...
- How To Use the Door Closing Speed Tool
-
Error/Omission: Doors into and within guest rooms that are not accessible guest rooms do not provide at least 32" clear opening width.
Error/Omission: Doors into and within guest rooms that are not accessible guest rooms do not provide at least 32" clear opening width....
-
D6
If an entry has a vestibule, is there a 30-inch by 48-inch clear floor space inside the vestibule where a wheelchair or scooter user can be outside the swing of a hinged door?...
-
LaCantina Multi-slide Thermally Controlled Aluminum Sliding Door System Pocket Door Model
Requires the Premium User plan or above. (Login or upgrade your account!)
-
Kickplates
Kickplates Recommendation: Some people with disabilities may use walkers or wheelchair footrests to push through doors, particularly those with closers....
-
11B-404.2.8.2 Spring hinges
Door and gate spring hinges shall be adjusted so that from the open position of 70 degrees, the door or gate shall move to the closed position in 1.5 seconds minimum....
-
4.34.2(6)
(6) Doors to and in accessible spaces that are intended for passage shall comply with 4.13, except that the provisions of 4.13.9 apply only to the doors at accessible entrances to the unit...
-
7a.
Is the clear width for the door opening at least 32 inches measured when the door is open 90 degrees? [ADA Stds 4.1.3(7), 4.13.5] Yes _____ No _____...
-
404.2.8.2 Spring Hinges
Door and gate spring hinges shall be adjusted so that from the open position of 70 degrees, the door or gate shall move to the closed position in 1.5 seconds minimum....
-
404.2.8.2 Spring Hinges
Door and gate spring hinges shall be adjusted so that from the open position of 70 degrees, the door or gate shall move to the closed position in 1.5 seconds minimum....
-
g-i
Is the clear width for the door opening at least 32 inches measured when the door is open 90 degrees? [ADA Standards §§ 4.1.3(7), 4.13.5] Yes No...
-
11B-404.2.8.2 Spring hinges
Door and gate spring hinges shall be adjusted so that from the open position of 70 degrees, the door or gate shall move to the closed position in 1.5 seconds minimum....
-
11B-404.2.8.2 Spring hinges
Door and gate spring hinges shall be adjusted so that from the open position of 70 degrees, the door or gate shall move to the closed position in 1.5 seconds minimum....
-
404.3.3 Thresholds
Thresholds and changes in level at doorways shall comply with 404.2.5.
-
11B-404.3.3 Thresholds
Thresholds and changes in level at doorways shall comply with Section 11B-404.2.5.
-
404.3.3 Thresholds
Thresholds and changes in level at doorways shall comply with 404.2.5.