Wheelchair storage spaces complying with Section 11B-305 shall be provided in or adjacent to unload areas for each required transfer device and shall not overlap any required means of egress...
Search Results "Line Spacing (Raised)"
-
11B-1002.6.3 Wheelchair storage space
-
11B-1002.6.3 Wheelchair storage space
Wheelchair storage spaces complying with Section 11B-305 shall be provided in or adjacent to unload areas for each required transfer device and shall not overlap any required means of egress...
-
R302.4 Passing Spaces
R302.4 Passing Spaces. Where the clear width of pedestrian access routes is less than 1.5 m (5.0 ft), passing spaces shall be provided at intervals of 61 m (200.0 ft) maximum....
-
T702.6 Character Spacing
Character spacing shall be measured between the two closest points of adjacent characters, excluding word spaces....
-
Clear Deck Space
Clear Deck Space The base of the transfer platform must have a clear deck space adjacent to it that is 60 by 60 inches minimum, with a slope not steeper than 1:48 so a person using a...
-
Ground Surfaces: ADA Standard Section 1008.2.6
Ground surfaces on accessible routes, clear floor or ground spaces, and turning spaces shall comply with 1008.2.6. Advisory 1008.2.6 Ground Surfaces....
-
Raised and Brailled Characters and Pictorial Symbol Signs [4.30.4]
Recommendations: Raised borders can confuse tactile reading of raised (and Braille) characters. They should be avoided or spaced away from raised text....
-
1009.5.2 Transfer Space
1009.5.2 Transfer Space....
-
11B-1002.5.4 Wheelchair storage space
Wheelchair storage spaces complying with Section 11B-305 shall be provided in or adjacent to unload areas for each required amusement ride seat designed for transfer and shall not overlap...
-
11B-1002.5.4 Wheelchair storage space
Wheelchair storage spaces complying with Section 11B-305 shall be provided in or adjacent to unload areas for each required amusement ride seat designed for transfer and shall not overlap...
-
R305.1.2 Dome Spacing
R305.1.2 Dome Spacing....
-
304 Turning Space
[See subsections ...]
-
Sec.36.308(a)(3)
(3) The requirements of paragraph (a) of this section shall not be interpreted to exceed the standards for alterations in subpart D of this part.
-
705.1.2 Dome Spacing
705.1.2 Dome Spacing....
-
CLEAR FLOOR SPACE
CLEAR FLOOR SPACE. [DSA-AC] The minimum unobstructed floor or ground space required to accommodate a single, stationary wheelchair and occupant....
-
1009.5.2 Transfer Space
A transfer space of 60 inches (1525 mm) minimum by 60 inches (1525 mm) minimum with a slope not steeper than 1:48 shall be provided at the base of the transfer platform surface and shall...
-
Additional Technical Criteria Considered for Handrails on Ramps
M303.3.3.5 would require handrails to be provided on each side of the ramp when the vertical rise of the ramp exceeds 6 inches. This is consistent with the 2004 ADA and ABA...
-
Clear Floor or Ground Space
Clear Floor or Ground Space At least one clear floor or ground space (30 inches by 48 inches minimum) must be provided at each location that has a railing height of 34 inches maximum....
-
11B-203.4 Limited access spaces
Spaces not customarily occupied and accessed only by ladders, catwalks, crawl spaces, or very narrow passageways shall not be required to comply with these requirements or to be on an accessible...
-
11B-203.4 Limited access spaces
Spaces not customarily occupied and accessed only by ladders, catwalks, crawl spaces, or very narrow passageways shall not be required to comply with these requirements or to be on an accessible...
-
R304.5.5 Clear Space
R304.5.5 Clear Space....
-
E202.4 ICT Functions Located in Maintenance or Monitoring Spaces
Where status indicators and operable parts for ICT functions are located in spaces that are frequented only by service personnel for maintenance, repair, or occasional monitoring of equipment...
-
705.1.2 Dome Spacing
Truncated domes in a detectable warning surface shall have a center-to-center spacing of 1.6 inches (41 mm) minimum and 2.4 inches (61 mm) maximum, and a base-to-base spacing of 0.65 inch...
-
705.1.2 Dome Spacing
Truncated domes in a detectable warning surface shall have a center-to-center spacing of 1.6 inches (41 mm) minimum and 2.4 inches (61 mm) maximum, and a base-to-base spacing of 0.65 inch...