key surfaces shall have tactile symbols as follows: Enter or Proceed key: raised circle; Clear or Correct key: raised left arrow; Cancel key: raised letter ex; Add Value key: raised plus sign...
Search Results "Hoistway Sign"
Commonly Searched Documents
-
Tactile Symbols: ADA Standard Section 707.6.3.2
-
11B-707.6.3.2 Tactile symbols
key surfaces shall have tactile symbols as follows: Enter or Proceed key: raised circle; Clear or Correct key: raised left arrow; Cancel key: raised letter ex; Add Value key: raised plus sign...
-
Amusement Rides: ADA Standard Section 216.12
Section 216.12 covers scoping requirements in the current ADA Standards for signs at amusement rides.
-
11B-703.6 Pictograms
Pictograms and other symbols, such as the International Symbol of Accessibility (ISA), which are included on signs with raised characters and Braille are not required to be raised....
-
11B-207.1 General
Directional signs shall be provided in compliance with Chapter 10, Section 1009.10. Advisory 11B-207 Accessible means of egress....
-
1009.9 Signage
Signage indicating special accessibility provisions shall be provided as shown: Each door providing access to an area of refuge from an adjacent floor area shall be identified by a sign...
-
407.2.2.2 Visible Signals
Destination-oriented elevators shall be permitted to have signals visible from the floor area adjacent to the hoistway entrance. 2....
-
407.2.2.1 Visible and Audible Signals
A visible and audible signal shall be provided at each hoistway entrance to indicate which car is answering a call and the car's direction of travel....
-
407.2.2.2 Visible Signals
Destination-oriented elevators shall be permitted to have signals visible from the floor area adjacent to the hoistway entrance. 2....
-
407.2.2.1 Visible and Audible Signals
A visible and audible signal shall be provided at each hoistway entrance to indicate which car is answering a call and the car's direction of travel....
-
11B-703.7 Symbols of accessibility
Symbols of accessibility, such as the International Symbol of Accessibility (ISA), which are included on signs with raised characters and Braille are not required to be raised....
-
11B-407.4.9 Emergency communication
Emergency two-way communication systems between the elevator and a point outside the hoistway shall comply with ASME A17.1. [2010 ADAS] 407.4.9 Emergency Communication. ...
-
407.2.2.1 Visible and Audible Signals
A visible and audible signal shall be provided at each hoistway entrance to indicate which car is answering a call and the car's direction of travel....
-
4.10.6* Door Protective and Reopening Device
They shall be provided with a reopening device that will stop and reopen a car door and hoistway door automatically if the door becomes obstructed by an object or person....
-
4.10.13* Car Position Indicators
In elevator cars, a visual car position indicator shall be provided above the car control panel or over the door to show the position of the elevator in the hoistway....
-
4.10.13* CAR POSITION INDICATORS
In elevator cars, a visual car position indicator shall be provided above the car control panel or over the door to show the position of the elevator in the hoistway....
-
11B-407.4.9 Emergency communication
Emergency two-way communication systems between the elevator and a point outside the hoistway shall comply with ASME A17.1. [2010 ADAS] 407.4.9 Emergency Communication....
-
11B-407.4.9 Emergency communication
Emergency two-way communication systems between the elevator and a point outside the hoistway shall comply with ASME A17.1. [2010 ADA Standards] 407.4.9 Emergency Communication....
-
407.2.2.2 Visible Signals
Destination-oriented elevators shall be permitted to have signals visible from the floor area adjacent to the hoistway entrance. 2....
-
Attachment J: Access to Humboldt County Programs Housed in Others’ Facilities
Attachment J: Access to Humboldt County Programs Housed in Others’ Facilities
-
Means of Egress: ADA Standard Section 216.4
Section 216.4 covers scoping requirements in the current ADA Standards for signs for means of egress.
-
Installation Height and Location: ADA Standard Section 703.4
Signs with tactile characters shall comply with 703.4....
-
1010.2.13.1 Delayed egress locking system
A sign shall be provided on the door and shall be located above and within 12 inches (305 mm) of the door exit hardware: 6.3....
-
Check-Out Aisles: ADA Standard Section 216.11
Section 216.11 covers scoping requirements in the current ADA Standards for signs at check-out aisles.