Where a clear floor or ground space is located in an alcove or otherwise confined on all or part of three sides, additional maneuvering clearance shall be provided in accordance with Sections...
Search Results "Handrail Clearance"
Commonly Searched Documents
-
11B-305.7 Maneuvering clearance
-
Extended Ground or Deck Surface: ADA Standard Section 1005.3.2
Toe clearance shall be provided and shall be 30 inches (760 mm) wide minimum and 9 inches (230 mm) minimum above the ground or deck surface beyond the railing....
-
11B-1005.3.2 Extended ground or deck surface
Toe clearance shall be provided and shall be 30 inches (762 mm) wide minimum and 9 inches (229 mm) minimum above the ground or deck surface beyond the railing....
-
Picnic Tables [1011.2 and 1011.4]
Knee clearance must be at least 30 inches wide and 8 inches deep at 27 inches above the ground surface....
-
11B-1008.2 Accessible routes
Where accessible routes serve ground level play components, the vertical clearance shall be 80 inches (2032 mm) high minimum....
-
10. Vertical Clearance at Exterior Stairs
10. ...are all exterior stairs built so blind persons and persons with low vision will not hit their head(s) on the underside (i.e.: protected with a cane detectable warning, such as...
-
1132A.5 Maneuvering clearances at doors
[See subsections ...]
-
1132A.5 Maneuvering clearances at doors
[See subsections ...]
-
11B-812.4 Vertical clearance
Vehicle spaces, access aisles serving them, and vehicular routes serving them shall provide a vertical clearance of 98 inches (2489 mm) minimum....
-
11B-812.4 Vertical clearance
Vehicle spaces, access aisles serving them, and vehicular routes serving them shall provide a vertical clearance of 98 inches (2489 mm) minimum....
-
404.3.2 Maneuvering Clearance
Clearances at power-assisted doors and gates shall comply with 404.2.4....
-
4.26 Handrails, Grab Bars, and Tub and Shower Seats
[See subsections ...]
-
A4.26 Handrails, Grab Bars, and Tub and Shower Seats
[See subsections ...]
-
4.26 HANDRAILS, GRAB BARS, AND TUB AND SHOWER SEATS
[See subsections ...]
-
A4.26 HANDRAILS, GRAB BARS, AND TUB AND SHOWER SEATS
[See subsections ...]
-
404.3.2 Maneuvering Clearance
Clearances at power-assisted doors and gates shall comply with 404.2.4....
-
Clear Width of Circulation Paths and Maneuvering Clearances at Wheelchair Spaces
., “sufficient clearances”) with quantified minimum clearances, nonetheless expressed some skepticism that such clearances would be adequate to accommodate all types of mobility devices,...
-
11B-606.2 Clear floor space
A clear floor space complying with Section 11B-305, positioned for a forward approach, and knee and toe clearance complying with Section 11B-306 shall be provided. Exceptions: 1....
-
11B-307.4 Vertical clearance
Vertical clearance shall be 80 inches (2032 mm) high minimum. Guardrails or other barriers shall be provided where the vertical clearance is less than 80 inches (2032 mm) high....
-
11B-604.3.1 Size
Clearance around a water closet shall be 60 inches (1524 mm) minimum measured perpendicular from the side wall and 56 inches (1422 mm) minimum measured perpendicular from the rear wall....
-
Common Problems with Routes to Building Entrances
Ø Ramps are too steep or go too long without level rest areas; handrails are not provided on both sides....
-
Can maneuvering for a forward approach be provided when there is space at least 60” deep in front of a door?
Space at least 60” deep in front of a door that is unobstructed on approach sides will provide sufficient depth for a forward approach if appropriate strike-side clearance is provided; but...
-
M303.2.4.2.2 Height
Wheelchair spaces shall include toe clearance 9 inches (230 mm) high minimum above the floor measured to a depth of 6 inches (150 mm) maximum measured from the toe end of the wheelchair...
-
1011.4.2 Wheelchair Space
Wheelchair spaces shall be positioned for a forward approach to the table and provide knee and toe clearance complying with 306 under the table....