In a wheelchair accessible compartment with a door located in the front wall or partition (facing the water closet), either in-swinging or out-swinging, a minimum 60 inches (1524 mm) wide...
Search Results "Entry Door (FHA)"
-
11B-604.8.1.1.3 Maneuvering space with end-opening door
-
Smooth Surface
Exceptions from this requirement are recognized for sliding doors (Exception 1), certain tempered glass doors without stiles (Exception 2), doors and gates that do not extend to within 10...
-
409.3.1 Power Operation
Elevator car and hoistway doors and gates shall be power operated and shall comply with ANSI/BHMA A156.19 (1997 or 2002 edition) (incorporated by reference, see "Referenced Standards" in...
-
409.3.1 Power Operation
Elevator car and hoistway doors and gates shall be power operated and shall comply with ANSI/BHMA A156.19 (1997 or 2002 edition) (incorporated by reference, see "Referenced Standards" in...
-
1132A.8 Hand-activated door hardware
Hand-activated door latching, locking and opening hardware shall be centered between 30 inches (762 mm) and 44 inches (1118 mm) above the floor....
-
1132A.8 Hand-activated door hardware
Hand-activated door latching, locking and opening hardware shall be centered between 30 inches (762 mm) and 44 inches (1118 mm) above the floor....
- Safepath EZ Edge™ Transition
-
1132A.3, Item 5
A pair of doors, manual or automatic, must have at least one leaf which provides a clear width of not less than 32 inches (813 mm), measured with the door positioned at an angle of 90 degrees...
-
1132A.3, Item 5
A pair of doors, manual or automatic, must have at least one leaf which provides a clear width of not less than 32 inches (813 mm), measured with the door positioned at an angle of 90 degrees...
-
Compliance Determinations by State and Local Jurisdictions
Comment. A few commenters questioned the role of States and units of local government in determining compliance with the Act's accessibility requirements. The commenters noted that...
-
5.8.1.2.2 Single Ramped Entry - Edge Protection on the Platform and Platform Sides Recommendations
5.8.1.2.2 Single Ramped Entry - Edge Protection on the Platform and Platform Sides Recommendations The Committee recommends a two-inch high edge protection on the back of the platform...
-
4.1.2(7)
(7) Doors: (a) At each accessible entrance to a building or facility, at least one door shall comply with 4.13....
-
11B-213.3.1.2 Toilet compartments with urinal compartments
At all compartments not required to comply with Section 11B-604.8 or Section 11B-605.5, compartment doors shall be in-swinging and self-closing....
-
11B-213.3.1.2 Toilet compartments with urinal compartments
At all compartments not required to comply with Section 11B-604.8 or Section 11B-605.5, compartment doors shall be in-swinging and self-closing....
-
Maneuvering Clearances [§404.2.4]
Maneuvering Clearances [§404.2.4] Required maneuvering clearances provide space for opening and proceeding through doors, doorways, and gates using wheelchairs and other mobility aids...
- AquaTrek2 ADA Wading Pool Ramp
-
Door Clear Width
Door Clear Width Open the door 90 degrees, measure from the face of the door to the edge of the door stop....
-
703.4.2 Location
Where a tactile sign is provided at a door, the sign shall be located alongside the door at the latch side....
-
Are spring hinges and gravity hinges considered “closers” in determining the size of maneuvering clearances?
Some approaches require additional maneuvering clearances when a door or gate is equipped with a closer because of the additional force that must be counteracted in proceeding through doors...
-
Technical Memorandum TM 2017-25 Door and Gate Surfaces
TAS 404.2.10 also includes Exceptions for (1) sliding doors, (2) tempered glass doors (3) doors and gates which do not extend to within 10 inches of the finish floor, and (4) existing doors...
-
H25
Is the clear width of the door at least 32 inches (measured between the face of the door and the edge of the opening) when the door is open 90 degrees?...
-
Floor or Ground Surface: ADA Standard Section 404.2.4.4
Section 404.2.4.4 covers the current ADA Standards for floor or ground surfaces at door maneuvering clearances.
- Retail Store Disability Access; Dawn Secret Treasures: BigBell
-
Doors, Doorways, and Gates
Section 206.5 provides scoping requirements for doors, doorways, and gates....