Elevator hoistway and car doors shall open and close automatically....
Search Results "End-Opening Door"
Commonly Searched Documents
-
11B-411.3.2 Operation
-
11B-411.3.2 Operation
Elevator hoistway and car doors shall open and close automatically....
-
Other Requirements in the ADA Standards
Automated Doors Maneuvering clearance is required on the egress side of automated doors unless they are equipped with standby power or they stay open in power-off mode (§404.3.2)...
- ADAEZ Pro Plus Automatic Door Opener Quick Tip Door Arm Pivot Variations Video
- ADAEZ Pro Plus Automatic Door Opener Quick Tip Adjusting Spring Door Tension Video
-
1132A.3, Item 5
A pair of doors, manual or automatic, must have at least one leaf which provides a clear width of not less than 32 inches (813 mm), measured with the door positioned at an angle of 90 degrees...
-
1132A.3, Item 5
A pair of doors, manual or automatic, must have at least one leaf which provides a clear width of not less than 32 inches (813 mm), measured with the door positioned at an angle of 90 degrees...
-
H3
[ADA Standards § 4.13.9] Yes No If No, can the door be propped open without compromising privacy, or can the hardware be modified by adding new accessible hardware, or adapting...
-
4.1.2(7)
(7) Doors: (a) At each accessible entrance to a building or facility, at least one door shall comply with 4.13....
- Figure 404.2.3 Clear Width of Doorways – Drawing from the U.S. Access Board
-
M301.2.3.1 End Transfer Surface
End transfer surfaces shall be 28 inches (710 mm) wide minimum and 17 inches (430 mm) long minimum. ...
-
4.10.9 Floor Plan of Elevator Cars
Acceptable door opening and inside dimensions shall be as shown in Fig. 22....
-
4.10.9 FLOOR PLAN OF ELEVATOR CARS
Acceptable door opening and inside dimensions shall be as shown in Fig. 22....
-
Doors, Doorways, and Gates
Section 206.5 provides scoping requirements for doors, doorways, and gates....
-
SECTION 1008 DOORS, GATES AND TURNSTILES
SECTION 1008 DOORS, GATES AND TURNSTILES [DSA-AC] In addition to the requirements of this section, means of egress, which provide access to, or egress from, buildings or facilities where...
-
Floor or Ground Surface: ADA Standard Section 404.2.4.4
Section 404.2.4.4 covers the current ADA Standards for floor or ground surfaces at door maneuvering clearances.
-
SECTION 1132A DOORS
[See subsections ...]
-
SECTION 1132A DOORS
[See subsections ...]
- Doug Mockett & Company SDH1 Sliding Door Hardware
-
1132A.4.1 Thresholds
Thresholds at the primary entry and required exit doors shall be no higher than ½ inch (12.7 mm)....
-
11B-411.3.3 Reopening device
Elevator doors shall be provided with a reopening device complying with Section 11B-411.3.3 that shall stop and reopen a car door and hoistway door automatically if the door becomes obstructed...
-
Doorways at Landings [§405.7.5]
Doorways at Landings [§405.7.5] Required door maneuvering clearances can overlap ramp landings (it is advisable to locate the swing of doors outside ramp landings for greater safety)....
-
Exit Doors: ADA Standard Section 216.4.1
Section 216.4.1 covers scoping requirements in the current ADA Standards for signs at exit doors.
-
D. Captioning and Video Description Generally
Open captions are similar to subtitles in that the text of the dialog is visible to everyone in the theater....