Inside dimensions of elevator cars and clear width of elevator doors shall comply with Section 11B-407.4.1....
Search Results "Door Clear Width"
-
11B-411.4.1 Car dimensions
-
Usable Door
One commenter stated that a clear definition of "usable door" is required. Response....
-
Door Maneuvering Clearance
It includes tables that specify these clearances according to the type of door, doorway, or gate (swinging, sliding, folding, and doorways without doors or gates) and the approach (front...
-
Problem One (Voting Area)
Problem One: The voting area is in a small room and the accessible voting machine is only two feet from the check-in table. Solution: Relocate the voting area to a larger space...
-
Preferred Seat Widths
The seat width percentiles remained the same for transfers to and from the station and within each protocol....
-
11B-406.5.2 Width
The clear width of curb ramp runs (excluding any flared sides), blended transitions, and turning spaces shall be 48 inches (1219 mm) minimum....
-
11B-406.5.2 Width
The clear width of curb ramp runs (excluding any flared sides), blended transitions, and turning spaces shall be 48 inches (1219 mm) minimum....
-
11B-406.5.2 Width
The clear width of curb ramp runs (excluding any flared sides), blended transitions, and turning spaces shall be 48 inches (1219 mm) minimum....
-
11B-604.8.2.2 Doors
11B-604.8.2.2 Doors....
-
11B-407.3 Elevator door requirements
Hoistway and car doors shall comply with Section 11B-407.3....
-
11B-407.3 Elevator door requirements
Hoistway and car doors shall comply with Section 11B-407.3....
-
11B-407.3 Elevator door requirements
Hoistway and car doors shall comply with Section 11B-407.3....
-
11B-604.8.2.2 Doors
Toilet compartment doors, including door hardware, shall comply with Section 11B-404, except that if the approach is to the latch side of the compartment door, clearance between the door...
-
4.13.6 MANEUVERING CLEARANCES AT DOORS
The floor or ground area within the required clearances shall be level and clear....
-
4.13.9* DOOR HARDWARE
When sliding doors are fully open, operating hardware shall be exposed and usable from both sides....
-
Door and Gate Hardware
Section 404.2.7 also covers the operating characteristics and height of door and gate hardware....
-
4.13.6 Maneuvering Clearances at Doors
The floor or ground area within the required clearances shall be level and clear....
-
11B-604.8.2.2 Doors
Toilet compartment doors, including door hardware, shall comply with Section 11B-404, except that if the approach is to the latch side of the compartment door, clearance between the door...
-
1007.3 Stairways
In order to be considered part of an accessible means of egress, a stairway between stories shall have a clear width of 48 inches (1219 mm) minimum between handrails and shall either incorporate...
-
Re: 404.2.6 Doors in Series and Gates in Series
My understanding is that it was written to keep wheelchair users from having to fight two doors at once. ...
-
11B-404.2.8.1 Door closers and gate closers
Door closers and gate closers shall be adjusted so that from an open position of 90 degrees, the time required to move the door to a position of 12 degrees from the latch is 5 seconds minimum...
-
11B-404.2.8.1 Door closers and gate closers
Door closers and gate closers shall be adjusted so that from an open position of 90 degrees, the time required to move the door to a position of 12 degrees from the latch is 5 seconds minimum...
-
Doors in a Series
A few commenters expressed concern that the Guidelines did not provide design for an entrance that consists of a series of more than one door....
-
K1
K1. Is there an accessible route, at least 36 inches wide, that connects each of the shelter activity areas with the food service and eating areas (it may narrow to 32 inches wide...