Exceptions: Existing locks shall be permitted in any location at existing glazed doors without stiles, existing overhead rolling doors or grilles, and similar existing doors or grilles...
Search Results "Door Clear Width"
-
11B-404.2.7 Door and gate hardware
-
Seat Width Evaluation
The additional platform width may also have been needed to accommodate larger individuals; however the size of the individual and seat width of the wheelchair were not measured and therefore...
-
11B-405.5 Clear width
The clear width of a ramp run shall be 48 inches (1219 mm) minimum. Exceptions: 1....
-
11B-405.5 Clear width
The clear width of a ramp run shall be 48 inches (1219 mm) minimum....
-
11B-405.5 Clear width
The clear width of a ramp run shall be 48 inches (1219 mm) minimum. Exceptions: 1. ...
-
604.8.2.2 Doors
604.8.2.2 Doors....
-
Compartment Doors
Specifications are provided for doors, including their location....
-
29.1 Q. Is it acceptable to design a bathroom with an in-swinging 2'10 door which can be retrofitted to swing out in order to provide the necessary clear floor space in the bathroom?
Thus, for a bathroom, there must be sufficient maneuvering space and clear floor space so that a person using a wheelchair or other mobility aid can enter and close the door, use the fixtures...
-
604.8.2.2 Doors
Toilet compartment doors, including door hardware, shall comply with 404, except that if the approach is to the latch side of the compartment door, clearance between the door side of the...
-
604.8.2.2 Doors
Toilet compartment doors, including door hardware, shall comply with 404, except that if the approach is to the latch side of the compartment door, clearance between the door side of the...
-
11B-410.3 Clear floor space
Clear floor space in platform lifts shall comply with Section 11B-305....
-
11B-410.3 Clear floor space
Clear floor space in platform lifts shall comply with Section 11B-305....
-
Manual Doors and Gates [§404.2]
Manual Doors and Gates [§404.2]...
-
404.3 Automatic and Power-Assisted Doors and Gates
404.3 Automatic and Power-Assisted Doors and Gates. Automatic doors and automatic gates shall comply with 404.3....
-
Break Out Opening: ADA Standard Section 404.3.6
Section 404.3.6 covers the current ADA Standards for the break out openings at swinging or sliding doors and gates.
-
California/ADA Plan Review Tool - Door Maneuvering Clearances
California/ADA Plan Review Tool - Door Maneuvering Clearances Click here to view/download the pdf "California/ADA Plan Review Tool - Door Maneuvering Clearances" (250 KB) * * * * *...
-
407.3 Elevator Door Requirements
Hoistway and car doors shall comply with 407.3....
-
407.3 Elevator Door Requirements
Hoistway and car doors shall comply with 407.3....
-
11B-404.3.6 Break out opening
Where doors and gates without standby power are a part of a means of egress, the clear break out opening at swinging or sliding doors and gates shall be 32 inches (813 mm) minimum when operated...
-
11B-404.3.6 Break out opening
Where doors and gates without standby power are a part of a means of egress, the clear break out opening at swinging or sliding doors and gates shall be 32 inches (813 mm) minimum when operated...
-
11B-404.3.7 Revolving doors, revolving gates, and turnstiles
Revolving doors, revolving gates, and turnstiles shall not be part of an accessible route....
-
11B-404.3.7 Revolving doors, revolving gates, and turnstiles
Revolving doors, revolving gates, and turnstiles shall not be part of an accessible route....
-
11B-404.3.7 Revolving doors, revolving gates, and turnstiles
Revolving doors, revolving gates, and turnstiles shall not be part of an accessible route....
-
11B-804.6.1 Clear floor or ground space
A clear floor or ground space complying with Section 11B-305 shall be provided at each kitchen appliance. Clear floor or ground spaces shall be permitted to overlap....