Where fire rings, grills, or fireplaces are constructed with raised edges or walls, the depth of the raised edge or wall shall be 10 inches (255 mm) maximum....
Search Results "Counter Depth"
Commonly Searched Documents
-
1011.5.3 Raised Edges or Walls
-
1011.5.3 Raised Edges or Walls
Where fire rings, grills, or fireplaces are constructed with raised edges or walls, the depth of the raised edge or wall shall be 10 inches (255 mm) maximum....
-
4.2.5 Raised Edge
Where fire rings, grills, or fireplaces are constructed with raised edges or walls, the depth of the raised edge or wall shall be 10 inches (255 mm) maximum....
-
5.2.1 Transfer Surface Size Recommendations for M301
The technical criteria do not address the overall width and depth of patient support surfaces because of the diverse shape and size of these surfaces....
- Ampetronic TalkPerfect Duplex Intercom, Speech Transfer System
-
Using the Tape Measure
A tape measure is used to measure the length, width, height, and depth of various elements including parking spaces and access aisles, routes, thresholds, doorways, and protruding objects...
-
4.34.6.4 WORK SURFACES
At least one 30 in (760 mm) section of counter shall provide a work surface that complies with the following requirements (see Fig. 50):...
-
11B-408.4.1 Car dimensions and doors
Elevator cars shall provide a clear width 42 inches (1067 mm) minimum and a clear depth 54 inches (1372 mm) minimum....
-
806 Transient Lodging Guest Rooms
Substantive changes made to this section revise requirements for: vanity counter spaces in accessible toilet or bathing rooms (806.2.4.1) wheelchair turning space (806.2.6...
-
Attachment I: Program Access in Existing Facilities
Attachment I: Program Access in Existing Facilities
-
4.17.3 SIZE AND ARRANGEMENT
Toilet stalls with a minimum depth of 56 in (1420 mm) (see Fig. 30(a)) shall have wall-mounted water closets....
-
305.7.2 Parallel Approach
Alcoves shall be 60 inches (1525 mm) wide minimum where the depth exceeds 15 inches (380 mm). Figure 305.7.2 Maneuvering Clearance in an Alcove, Parallel Approach...
-
305.7.1 Forward Approach
Alcoves shall be 36 inches (915 mm) wide minimum where the depth exceeds 24 inches (610 mm). Figure 305.7.1 Maneuvering Clearance in an Alcove, Forward Approach...
-
R404.7.1 Forward Approach
The clear space and additional maneuvering space shall be 915 mm (3.0 ft) wide minimum where the depth exceeds 610 mm (2.0 ft)....
-
R404.7.2 Parallel Approach
The clear space and additional maneuvering space shall be 1525 mm (5.0 ft) wide minimum where the depth exceeds 380 mm (1.25 ft)....
-
4.34.6.5(3)
(3) The depth of a sink bowl shall be no greater than 6-1/2 in (165 mm). Only one bowl of double- or triple-bowl sinks needs to meet this requirement....
-
Side Entry: ADA Standard Section 1002.4.4.2
For example, where a 42 inch (1065 mm) opening is provided, a minimum clear space of 60 inches (1525 mm) in length and 36 inches (915mm) in depth is needed to ensure adequate space for maneuvering...
-
11B-1002.4.4.2 Side entry
For example, where a 42 inch (1065 mm) opening is provided, a minimum clear space of 60 inches (1525 mm) in length and 36 inches (915mm) in depth is needed to ensure adequate space for maneuvering...
-
Example: Retail Facility
This example of a retail facility shows how scoping requirements for certain elements and spaces (sales counters and fitting rooms) apply and indicates employee work areas....
-
Pass Through Kitchen
Clearances for pass through kitchens address counters, appliances, or cabinets on two opposing sides....
-
3) Restaurants
Contains requirements for counters and bars, access aisles, food service lines, tableware and condiment areas, raised speaker's platforms, and vending machine areas (but not controls)....
-
11B-305.7.2 Parallel approach
Alcoves shall be 60 inches (1524 mm) wide minimum where the depth exceeds 15 inches (381 mm). FIGURE 11B-305.7.2 MANEUVERING CLEARANCE IN AN ALCOVE, PARALLEL APPROACH...