Is the clear width of the door at least 32 inches (measured between the face of the door and the edge of the opening) when the door is open 90 degrees?...
Search Results "Clear"
Commonly Searched Documents
-
H25
-
1009.3.3 Handrails
The clear width between required handrails shall be 33 inches (840 mm) minimum and 38 inches (965 mm) maximum. EXCEPTIONS: 1....
-
1009.3.3 Handrails
The clear width between required handrails shall be 33 inches (840 mm) minimum and 38 inches (965 mm) maximum. EXCEPTIONS: 1....
-
1007.3.2 Golf Club Reach Range Area
All areas within holes where golf balls rest shall be within 36 inches (915 mm) maximum of a clear floor or ground space 36 inches (915 mm) wide minimum and 48 inches (1220 mm) long minimum...
-
11B-1007.3.2 Golf club reach range area
All areas within holes where golf balls rest shall be within 36 inches (914 mm) maximum of a clear floor or ground space 36 inches (914 mm) wide minimum and 48 inches (1219 mm) long minimum...
-
11B-1007.3.2 Golf club reach range area
All areas within holes where golf balls rest shall be within 36 inches (914 mm) maximum of a clear floor or ground space 36 inches (914 mm) wide minimum and 48 inches (1219 mm) long minimum...
-
4.4.6 Surface
The surface of the clear floor or ground space for benches shall be firm and stable. The type of surface should be appropriate to the setting and level of development....
-
6.3(2)
(2) Each one-bed room shall have a minimum clear floor space of 36 in (915 mm) along each side of the bed, and 42 in (1065 mm) between the foot of the bed and the wall....
-
1007.3.2 Golf Club Reach Range Area
All areas within holes where golf balls rest shall be within 36 inches (915 mm) maximum of a clear floor or ground space 36 inches (915 mm) wide minimum and 48 inches (1220 mm) long minimum...
-
11B-813.2.1.5 Obstructions
When deployed, changing tables shall not obstruct the required width of an accessible route except as allowed by Section 11B-307.2.
-
6.3(3)
(3) Each bedroom shall have adequate space to provide a minimum clear floor space of 36 in (915 mm) along each side of the bed and to provide an accessible route complying with 4.3.3 to...
-
11B-1007.3.2 Golf club reach range area
All areas within holes where golf balls rest shall be within 36 inches (914 mm) maximum of a clear floor or ground space 36 inches (914 mm) wide minimum and 48 inches (1219 mm) long minimum...
-
1007.3.2 Golf Club Reach Range Area
All areas within holes where golf balls rest shall be within 36 inches (915 mm) maximum of a clear floor or ground space 36 inches (915 mm) wide minimum and 48 inches (1220 mm) long minimum...
-
Guestroom Doors
Guestroom Doors Common Problem: Doors and doorways into and within all guestrooms and suites, including bathroom doors and doorways, do not allow 32 inches of clear opening width....
-
Reach Ranges (Advisory)
Reach Ranges (Advisory) The play area guidelines include advisory information on recommended reach ranges. Reach ranges are the recommended designated regions of space that a...
-
7.3(2)
(2) Clear aisle width for accessible check-out aisles shall comply with 4.2.1 and maximum adjoining counter height shall not exceed 38 in (965 mm) above the finish floor....
-
11B-305.2 Floor or ground surfaces
Floor or ground surfaces of a clear floor or ground space shall comply with Section 11B-302....
-
Accessible Route
accessible route but where they are required to comply with 4.9, it is recommended that routes to them meet the requirements for accessible routes since certain specifications, such as clear...
-
6.3(3)
(3) Each two-bed room shall have a minimum clear floor space of 42 in (1065 mm), preferably 48 in (1220 mm), between the foot of the bed and the wall; 36 in (915 mm) between the side of...
-
11B-224.1.2 Guest room doors and doorways
Because of the social interaction that often occurs in lodging facilities, an accessible clear opening width is required for doors and doorways to and within all guest rooms, including those...
-
§ 38.113(a)(1)
accessible by §38.111(a) and where the spaces required by §38.111(d) of this part are located, and at least one adjacent doorway into coach passenger compartments shall have a minimum clear...
- Figure 1007.3.2 Golf Club Reach Range Area – Drawing from the U.S. Access Board
-
A. Entry Doors
Do entry doors, connecting room doors, and interior doors (except doors to shallow closets) into and within all guestrooms and suites allow 32" clear passage width so persons who use wheelchairs...
- Pilot Rock CN-R/R Round Receptacle Perforated Steel