Space to accommodate wheelchairs and mobility aids may be provided within the normal area used by standees and designation of specific spaces is not required....
Search Results "Employee Use"
-
§ 38.83(a)(1) General
-
§ 37.42(d)(3)
The FTA and the FRA may make this determination jointly in any situation in which both a commuter rail system and an intercity or high-speed rail system use the tracks serving the platform...
-
11B-233.3.1.2.5 Multi-story residential dwelling units in buildings with no elevator
In non-elevator buildings in public housing facilities, a minimum of 10 percent but not less than one of the ground floor multi-story residential dwelling units shall be calculated using...
-
11B-406 Curb ramps, blended transitions and islands
Standards] 406 Curb Ramps ETA Editor's Note The differences between 2010 ADA Standards Section 406 and CBC Section 11B-406 are numerous, as indicated by the italicized text, which is used...
-
11B-705.1.1.3 Color and contrast
The material used to comply with this section shall be an integral part of the detectable warning surface. Exceptions: 1....
-
217.4 TTYs
In some instances one TTY can be used to satisfy more than one of these requirements. For example, a TTY required for a bank can satisfy the requirements for a building....
-
217.4 TTYs
In some instances one TTY can be used to satisfy more than one of these requirements. For example, a TTY required for a bank can satisfy the requirements for a building....
- American Standard Colony PRO Two-Handle Kitchen Faucet with High-Arc Swivel Spout 7074.550
- Corbin Russwin Inc. ED8000 Pushpad Exit Device
- Cavity Sliders USA Inc. FH Ceiling Mount Track
- Sigma Home Products SCD-1 Cup Dispenser
- Plum Lightpad Dimmer
- Simple Pump Company ADA 100 Simple Water Pump
- Cold Plasma Clean Technology Animation
-
[2010 ADAS] 105.2.1 ANSI/BHMA
ANSI/BHMA A156.10-1999 applies to power operated doors for pedestrian use which open automatically when approached by pedestrians....
-
11B-704.3 Volume control telephones
If the microphone in the handset is not being used, a mute button that temporarily turns off the microphone can also reduce the amount of background noise which the person hears in the earpiece...
-
11B-410.1 General
Because an accessible route requires an 80 inch (2030 mm) vertical clearance, care should be taken in selecting lifts as they may not be equally suitable for use by people using wheelchairs...
-
6.3 Examinations and Inquiries Before Employment
This prohibition is necessary because the results of such inquiries and examinations frequently are used to exclude people with disabilities from jobs they are able to perform....
-
304 Turning Space
They argued that wheelchairs and other mobility devices are becoming larger and that more individuals with disabilities are using electric three and four-wheeled scooters which cannot utilize...
-
Assistive Listening Systems
Induction loop systems use a wire loop to receive input from a sound source and transmit sound by creating a magnetic field within the loop....
-
PART 4: ACCESSIBLE MEDICAL EQUIPMENT
This section provides examples of accessible medical equipment and how it is used by people with mobility disabilities....
-
11B-221.2.3 Lines of sight and dispersion
Consistent with the overall intent of the ADA, individuals who use wheelchairs must be provided equal access so that their experience is substantially equivalent to that of other members...
-
M101.2 Application (Section-by-Section Analysis)
that sections M301 through M304 of the MDE Standards be applied to diagnostic equipment based on the patient position that the equipment supports during patient transfer and diagnostic use...
-
What other considerations are significant for persons with disabilities?
Materials such as gravel, wood chips, or sand, often used for outdoor walkways, are neither firm nor stable, nor can they generally be considered slip-resistant....