Section 307.2 covers the current ADA Standards for protrusion limits.
Search Results "Sign Clear Floor Space"
-
Protrusion Limits: ADA Standard Section 307.2
-
11B-307.2 Protrusion limits
Objects with leading edges more than 27 inches (686 mm) and not more than 80 inches (2032 mm) above the finish floor or ground shall protrude 4 inches (102 mm) maximum horizontally into...
-
Shower Compartment Seats: ADA Standard Section 610.3
Section 610.3 covers the current ADA Standards for shower compartment seats.
-
Height: ADA Standard Section 704.4.1
When in use, the touch surface of TTY keypads shall be 34 inches (865 mm) minimum above the finish floor....
-
Expert Report of Jeromy G. Murphy, American Construction Investigations, LTD (August 6, 2018)
Drop-off: There is no accessible route from the vehicle pull-up space to the entrance as there is no curb ramp provided from the vehicle pull-up space and access aisle to the sidewalk and...
-
3.6 Youngstown Tinseltown 7, 7401 Market Street, Boardman, Ohio
3.6 Youngstown Tinseltown 7 7401 Market Street, Boardman, Ohio - In Auditorium 3, the four (4) wheelchair spaces shall be relocated one row farther back in the auditorium from their...
-
3.11 Tinseltown, 651 Medford Center, Medford, Oregon
3.11 Tinseltown 651 Medford Center, Medford, Oregon - In Auditorium 6, the four (4) wheelchair spaces shall be located one row further back in the auditorium from their current location...
-
5.1 GENERAL
Where practical, accessible tables should be distributed throughout the space or facility....
-
11B-707.7.1.1 Vertically mounted display screen
mounted vertically or no more than 30 degrees tipped away from the viewer, the center line of the display screen and other display devices shall be no more than 52 inches (1321 mm) above the floor...
-
603.4 Coat Hooks and Shelves
Shelves shall be located 40 inches (1015 mm) minimum and 48 inches (1220 mm) maximum above the finish floor. [ECTCR UFAS 4.25.3, Fig. 38]...
-
11B.707.7.1.2 Angle-mounted display screen
mounted between 30 degrees and 60 degrees tipped away from the viewer, the center line of the display screen and other display devices shall be no more than 44 inches (1118 mm) above the floor...
-
308.2.1 Unobstructed
Where a forward reach is unobstructed, the high forward reach shall be 48 inches (1220 mm) maximum and the low forward reach shall be 15 inches (380 mm) minimum above the finish floor or...
-
407.8.3.1 Unobstructed Forward Reach
maximum protrusion within the length of the vertical reference plane of the ICT, the operable part shall be 48 inches (1220 mm) high maximum and 15 inches (380 mm) high minimum above the floor...
-
M20
Is there a horizontal grab bar at least 36 inches long securely mounted behind the toilet 33 to 36 inches above the floor with one end no more than 6 inches from the side wall?...
-
Free-standing and Post-mounted Objects
Where objects are mounted above 27 inches from the ground or floor, overhangs are limited to 12 inches. This is based on standard measures for cane sweep....
-
ยง 38.113(d)(4) Exception
Retrofitted vehicles shall be coordinated with the platform in existing stations such that the horizontal gap shall be no greater than 4 inches and the height of the vehicle floor, under...
-
11B.707.7.1.1 Vertically mounted display screen
mounted vertically or tipped away from the viewer less than 30 degrees, the center line of the display screen and other display devices shall be no more than 52 inches (1321 mm) above the floor...
-
IMPLEMENTATION
The person signing this Agreement for H&R Block represents that he/she is authorized to bind H&R Block to this Agreement. 43....
-
E. Effective Communication
In some circumstances, qualified sign language or oral interpreters may be required by the ADA....
-
T504.1 General
Passenger access routes shall provide clearances that are sufficient to permit passengers using wheelchairs to move between wheelchair spaces and doorways that provide accessible boarding...
-
Side Approach
Sinks located in corners may not be fully within reach and the space to the rear of the side approach space cannot be reached....
-
608.2.2 Standard Roll-In Type Shower Compartments
Standard roll-in type shower compartments shall be 30 inches (760 mm) wide minimum by 60 inches (1525 mm) deep minimum clear inside dimensions measured at center points of opposing sides...
-
608.2.3 Alternate Roll-In Type Shower Compartments
Alternate roll-in type shower compartments shall be 36 inches (915 mm) wide and 60 inches (1525 mm) deep minimum clear inside dimensions measured at center points of opposing sides....
-
11B-406.6 Islands
The clear width of the accessible route at islands shall be 60 inches (1524 mm) wide minimum. Where curb ramps are provided, they shall comply with Section 11B-406....