Section 206.2.4 covers the scoping requirements in the most current ADA Standards for accessible routes connecting spaces and elements within a building.
Search Results "Water Closet Clear Floor Space"
-
Spaces and Elements: ADA Standard Section 206.2.4
-
Bus Shelters: ADA Standard Section 810.3
Bus shelters shall provide a minimum clear floor or ground space complying with 305 entirely within the shelter....
-
306.1 General
Where space beneath an element is included as part of clear floor or ground space or turning space, the space shall comply with 306....
-
11B-306.1 General
Where space beneath an element is included as part of clear floor or ground space or turning space, the space shall comply with Section 11B-306....
-
11B-306.1 General
Where space beneath an element is included as part of clear floor or ground space or turning space, the space shall comply with Section 11B-306....
-
Zurn Model Z1209 Vertical Offset Siphon Jet Water Closet Support System
Requires the Premium User plan or above. (Login or upgrade your account!)
-
2. Accessible lavatory with knee and toe space
Accessible lavatory with knee and toe space below, faucet controls usable with a loosely closed fist, clear floor space for front approach, and lowered mirror....
-
1134A.7, Item 3
The minimum height of water closet seats shall be 15 inches (381 mm) above the floor....
-
11B-407.4.7.1.5 Button spacing
A minimum clear space of 3/8 inch (9.5 mm) or other suitable means of separation shall be provided between rows of control buttons....
-
305.3 Size
The clear floor or ground space shall be 30 inches (760 mm) minimum by 48 inches (1220 mm) minimum. Figure 305.3 Clear Floor or Ground Space...
-
F. Clear Width
Do all entry doors to accessible guestrooms and other interior doors (except doors on shallow closets) allow at least 32" of clear passage width to accommodate persons who use wheelchairs...
- Figure 604.2 Water Closet Location – Drawing from the U.S. Access Board
-
11B-308.2.2 Obstructed high reach
Where a high forward reach is over an obstruction, the clear floor space shall extend beneath the element for a distance not less than the required reach depth over the obstruction....
-
11B-604.8.1.1.3 Maneuvering space with end-opening door
11B-604.8.1.1.3 Maneuvering space with end-opening door....
-
Parallel Approach: ADA Standard Section 904.4.1
A portion of the counter surface that is 36 inches (915 mm) long minimum and 36 inches (915 mm) high maximum above the finish floor shall be provided....
-
11B-810.3 Bus shelters
Bus shelters shall provide a minimum clear floor or ground space complying with Section 11B-305 entirely within the shelter....
-
604.5.2 Rear Wall
The rear wall grab bar shall be 36 inches (915 mm) long minimum and extend from the centerline of the water closet 12 inches (305 mm) minimum on one side and 24 inches (610 mm) minimum on...
-
306.1 General
Where space beneath an element is included as part of clear floor or ground space or turning space, the space shall comply with 306....
-
1134A.7, Item 3
The minimum height of water closet seats shall be 15 inches (381 mm) above the floor....
-
305.3 Size
The clear floor or ground space shall be 30 inches (760 mm) minimum by 48 inches (1220 mm) minimum. Figure 305.3 Clear Floor or Ground Space...
-
11B-809.10.7.3 Reinforcement for grab bars
Where water closets are placed adjacent to a side wall, reinforcement shall be installed on both sides or one side and the back....
-
Width [4.3.3.] and Passing Space [4.3.4]
A continuous minimum clear width of 36 inches is required for accessible routes, but a reduction to 32 inches is allowed for a linear distance of no more than 24 inches (e.g., a doorway)...
-
29. Bathroom Clear Floor Space
-
306.1 General
Where space beneath an element is included as part of clear floor or ground space or turning space, the space shall comply with 306....