In guest rooms having more than 25 beds, 5 percent minimum of the beds shall have clear floor space complying with Section 11B-806.2.3.
Search Results "Toe Clearance"
-
11B-224.3 Beds
-
§ 38.97(a)
Handrails shall be placed to provide a minimum 11/2 inches knuckle clearance from the nearest adjacent surface....
-
M301.4.2 Clearance Around Base
The base of the equipment shall provide a clearance 6 inches (150 mm) high minimum measured from the floor and 36 inches (915 mm) deep minimum measured from the edge of the examination surface...
-
M301.4.2 Clearance Around Base
The base of diagnostic equipment shall provide a clearance 6 inches (150 mm) high minimum measured from the floor and 36 inches (915 mm) deep minimum measured from the edge of the examination...
-
Protruding Objects [1016.9]
To prevent injuries to people who are blind or have low vision, whenever possible, maintain the vertical clearance free of tree branches a minimum of 80 inches above the ground surface along...
-
Entry Doors
Maneuvering clearances on either side of the door that comply with the ADA Standards must be provided....
-
Plumbing/Restrooms
accessories 11B-603 Clear floor space requirements at fixtures 11B-604 Compartment configuration side and end entry, toe...
- Access Board: Vertical Clearance for Protruding Objects
-
Can curbs be used to indicate areas with less than 80” of vertical clearance?
The standards specify a maximum height (27”) for the leading edge of barriers so they are within cane sweep, but a minimum height is not specified. Curbs may be mistaken for a step...
-
11B-805 Medical care and long-term care facilities
Handwashing fixtures, as sinks, are subject to Section 11B- 306.2.3, Exception 1 which states: "The toe clearance shall extend 19 inches minimum under sinks required to be accessible by...
-
11B-307.2 Protrusion limits
For example, awnings and their supporting structures cannot reduce the minimum required vertical clearance....
-
11B-307.2 Protrusion limits
For example, awnings and their supporting structures cannot reduce the minimum required vertical clearance....
-
307.2 Protrusion Limits
For example, awnings and their supporting structures cannot reduce the minimum required vertical clearance....
-
Point of Use Water Heaters and Knee Space
Are in line point of use hot water heaters required to be covered/shielded similar to how drains/hot water supply lines are?
-
§ 38.57(c)
width of the gripping surface of handrails and stanchions shall be 11/4 inches to 11/2 inches or provide an equivalent gripping surface and shall provide a minimum 11/2 inches knuckle clearance...
-
11B-404.2.4.1 Swinging doors and gates
Swinging doors and gates shall have maneuvering clearances complying with Table 11B-404.2.4.1....
-
11B-404.2.4.1 Swinging doors and gates
Swinging doors and gates shall have maneuvering clearances complying with Table 11B-404.2.4.1....
-
11B-604.3.1 Size
Clearance around a water closet shall be 60 inches (1524 mm) minimum measured perpendicular from the side wall and 56 inches (1422 mm) minimum measured perpendicular from the rear wall....
-
307.2 Protrusion Limits
For example, awnings and their supporting structures cannot reduce the minimum required vertical clearance....
-
11B-307.2 Protrusion limits
For example, awnings and their supporting structures cannot reduce the minimum required vertical clearance....
-
307.2 Protrusion Limits
For example, awnings and their supporting structures cannot reduce the minimum required vertical clearance....
-
1008.2 Accessible Routes
Where accessible routes serve ground level play components, the vertical clearance shall be 80 inches high (2030 mm) minimum....
-
1008.2 Accessible Routes
Where accessible routes serve ground level play components, the vertical clearance shall be 80 inches high (2030 mm) minimum....
-
Section D: Entrances
(§§309.4, 404.2.7) D3 On the pull side of the door, is there at least 18" of clearance provided to the side of the latch?...