Section 502.4 covers the current ADA Standards for the floor or ground surfaces of accessible parking spaces.
Search Results "Raised Curb"
-
Floor or Ground Surfaces: ADA Standard Section 502.4
-
11B-206.2.5 Restaurants, cafeterias, banquet facilities and bars
In restaurants, cafeterias, banquet facilities, bars, and similar facilities, an accessible route shall be provided to all functional areas, including raised or sunken areas, and outdoor...
-
11B-206.2.5 Restaurants, cafeterias, banquet facilities and bars
In restaurants, cafeterias, banquet facilities, bars, and similar facilities, an accessible route shall be provided to all functional areas, including raised or sunken areas, and outdoor...
-
EXHIBIT F ADA Maintenance Checklist
CURB RAMPS Curb ramps or ramps are used to allow customers with disabilities to enter the store if there is a curb or step in the accessible path....
-
11B-206.2.5 Restaurants, cafeterias, banquet facilities and bars
In restaurants, cafeterias, banquet facilities, bars, and similar facilities, an accessible route shall be provided to all functional areas, including raised or sunken areas, and outdoor...
-
5.8.1.2.1 Ramped Entry Slope
Raised platforms should have a ramp with slopes that do not exceed the following: Rise 0 to 1 ½ inches – 1:2 Slope Rise >1 ½ to 2 ½ inches – 1:8 Slope Rise >2 ½ inches – 1:12...
-
Section C: Exterior Route
(§307.4) C8 If the route crosses a curb, is there a curb ramp that is at least 36" wide with a slope no more than 1:12?...
-
Accessible Sidewalks 1: Pedestrians who use Wheelchairs
Requires the Registered User plan or above. Login!
- Figure 707.6.2 Numberic Key Layout – Drawing from the U.S. Access Board
-
Q8: Curb Ramp Replaced as Part of a Resurfacing Alteration and Adjacent Sidewalk
Q8: If an existing curb ramp is replaced as part of a resurfacing alteration, is there an obligation to address existing obstacles on the adjacent sidewalk at the same time? A8: No....
-
What types of facilities are covered by DOT’s ADA Standards (and are required to have detectable warnings on curb ramps)?
Curb ramp detectable warnings are required only at these facilities....
-
Q5.) What dimensions and conditions can practitioners reasonably consider to be compliant when the conditions, as constructed, do not meet the technical requirements exactly and there are no official, published, industry-developed tolerances?
of the materials and processes, David Ballast generally recommends a tolerance of 0.5% in the cross slope direction and 1.0% in the direction of travel for concrete or asphalt ramps and curb...
-
1. Width and Depth of Wheelchair Spaces
The Access Board sought input in questions 31, 32, and 33, regarding the required size of wheelchair spaces on raised platforms, the use of scooters on raised platforms, and the associated...
-
4.1.6(1)(b)
requirements) requiring major structural changes are planned or installed where none existed previously, then a means of accessible vertical access shall be provided that complies with 4.7, Curb...
-
11B-810.6.2 Routes and destinations
At least one tactile sign identifying the specific station and complying with Section 11B-703.2 _|Signs; Raised Characters|_ shall be provided on each platform or boarding area....
-
11B-810.6.2 Routes and destinations
At least one tactile sign identifying the specific station and complying with Section 11B-703.2 _|Signs; Raised Characters|_ shall be provided on each platform or boarding area....
-
5. Edge Protection
The MDE NPRM proposed edge protection on the ramps leading up to the raised platform (proposed M303.3.3.4), but did not require edge protection on the raised platforms themselves....
-
405.2 Slope
Ramp runs shall have a running slope not steeper than 1:12. EXCEPTION: In existing sites, buildings, and facilities, ramps shall be permitted to have running slopes steeper than...
-
405.2 Slope
Ramp runs shall have a running slope not steeper than 1:12. EXCEPTION: In existing sites, buildings, and facilities, ramps shall be permitted to have running slopes steeper than...
-
405.2 Slope
405.2 Slope. Ramp runs shall have a running slope not steeper than 1:12. EXCEPTION: In existing sites, buildings, and facilities, ramps shall be permitted to have running slopes...
-
2. Standing Supports
standing supports provision and while it supported the technical criteria in the proposed rule, the MDE Advisory Committee recommended adding additional criteria for standing supports on raised...
-
DSA Drawing 11B-406.6-10 Cut-Through Median Less Than 96 inches in Length with No Gutters (2016 CBC)
Requires the Premium User plan or above. (Login or upgrade your account!)
-
Circulation Paths Serving Exempted Spaces [§203]
catwalks, crawl spaces, or very narrow passageways; employee work areas under 300 sq. ft. that are elevated at least 7” as an essential functional condition of the space (excluding raised...
-
11B-250 Circulation paths
[See subsections ...]