accessible toilet is in a stall, does the stall measure at least 60" wide and 56" deep if it is wall mounted or 59" deep if it is floor mounted to allow persons who use wheelchairs to approach...
Search Results "Parallel Approach"
Commonly Searched Documents
-
G. Compartment Size
-
810.2.2 Dimensions
areas shall provide a clear length of 96 inches (2440 mm) minimum, measured perpendicular to the curb or vehicle roadway edge, and a clear width of 60 inches (1525 mm) minimum, measured parallel...
-
11B-404.2.4.1 Swinging doors and gates
TABLE 11B-404.2.4.1 MANEUVERING CLEARANCES AT MANUAL SWINGING DOORS AND GATES TYPE OF USE MINIMUM MANEUVERING CLEARANCE Approach...
- Norton Surface Mounted Medium Duty 8000 Series Door Closer
- TownSteel TDC 85 ALUMINUM Grade 1 Door Closer
- Door Scope® Door Viewer
- Bobrick Swing-Up Grab Bar B-4998
-
1008.3.1.3 Transfer Space
The 48 inch (1220 mm) long minimum dimension of the transfer space shall be centered on and parallel to the 24 inch (610 mm) long minimum side of the transfer platform....
-
1008.3.1.3 Transfer Space
The 48 inch (1220 mm) long minimum dimension of the transfer space shall be centered on and parallel to the 24 inch (610 mm) long minimum side of the transfer platform....
-
H12
least one of each type of dispenser, receptacle, or equipment, is there clear floor space at least 30 inches wide x 48 inches long adjacent to the control or dispenser (positioned either parallel...
-
Wheelchair Transfer
Wheelchair Transfer The manner of approach and transfer to water closets varies among people with disabilities....
-
Water Closet Clearances
the Department’s proposed final rules governing water closet clearances in single-user toilet rooms with in-swinging and out-swinging doors is to allow sufficient room for ‘‘side’’ or ‘‘parallel...
-
Water Closet Clearances
the Department's proposed final rules governing water closet clearances in single-user toilet rooms with in-swinging and out-swinging doors is to allow sufficient room for ‘‘side'' or ‘‘parallel...
-
Clear space
An angle of 0 degrees was given if the WMD was positioned parallel to the x-direction of the coordinate system (e.g. in parallel with the front edge of the platform)....
-
Suggestion by Eldon Tipping
Sample measurement lines were to be parallel or perpendicular to slopes shown on the drawings. Measurement lines that were parallel to slopes were to connect elevation control points....
-
Location: ADA Standard Section 604.9.1
Section 604.9.1 covers the current ADA Standards for the mounting location of children's use water closets.
-
11B-604.9.1 Location
Compartments shall be arranged for left-hand or right-hand approach to the water closet....
-
11B-406.5.10 Diagonal curb ramps
Diagonal or corner type curb ramps with returned curbs or other well-defined edges shall have the edges parallel to the direction of pedestrian flow....
-
Clear floor space
It appears that a minimum 6'-6" rear wall would be required if bench is parallel to a wall?...
-
4.10.12(3)
All floor buttons shall be no higher than 54 in (1370 mm) above the finish floor for side approach and 48 in (1220 mm) for front approach....
-
4 [§ 4.7.2]
The gutter slope is parallel to the ramp and perpendicular to the curb. The gutter may slope up to 5 percent towards the curb ramp, but not more....
-
1008.3.1.3 Transfer Space
The 48 inch (1220 mm) long minimum dimension of the transfer space shall be centered on and parallel to the 24 inch (610 mm) long minimum side of the transfer platform....
-
11B-1008.3.1.3 Transfer space
The 48 inch (1219 mm) long minimum dimension of the transfer space shall be centered on and parallel to the 24 inch (610 mm) long minimum side of the transfer platform....
-
R211.4 Accessible Parking Space and Passenger Loading Zone Signs
At accessible parallel parking spaces and accessible passenger loading zones, the signs shall be located at the head or foot of the parking space or passenger loading zone....