5.3.3 Transfer Sides Recommendations for M302 Description: Transfer side provisions are the same for M301 and M302 and require the transfer surface to be located to provide...
Search Results "Exam Room"
Commonly Searched Documents
-
5.3.3 Transfer Sides Recommendations for M302
-
5.2.3 Transfer Surface Measurement
5.2.3 Transfer Surface Measurement. The transfer surface should be measured from the center-point of each side of the transfer surface.
-
5.2.3 Transfer Surface Measurement Recommendation for M301 and M302
5.2.3 Transfer Surface Measurement Recommendation for M301 and M302 Description: The transfer surface size standard has two components: width and depth. The transfer surface...
-
M302.2.3 Transfer Sides
The transfer surface shall be located to provide options to transfer from a mobility device onto one short side (depth) and one long side (width) of the surface. Each transfer side...
-
M302.3.3 Head and Back Support
Where the diagnostic equipment is used in a reclined position, head and back support shall be provided. Where the incline of the back support can be modified while in use, head and...
-
11B-809.10.8.2 Floor space
A floor space 30 inches (762 mm) minimum by 48 inches (1219 mm) minimum shall be provided centered on the lavatory.
-
11B-213.3 Plumbing fixtures and accessories
Plumbing fixtures and accessories provided in a toilet room or bathing room required to comply with Section 11B-213.2 shall comply with Section 11B-213.3....
-
11B-224.1.2 Guest room doors and doorways
[2010 ADA Standards] 224.1.2 Guest Room Doors and Doorways....
-
Feature 1 - Parking and Passenger Drop-Off Areas
The accessible parking space has an adjacent and parallel access aisle that provides needed room for a person to open the car door fully and then to stand with the aid of a walker or crutches...
-
11B-224.1.2 Guest room doors and doorways
[2010 ADAS] 224.1.2 Guest Room Doors and Doorways. ...
-
11B-224.1.2 Guest room doors and doorways
[2010 ADAS] 224.1.2 Guest Room Doors and Doorways. ...
-
4.23.1 MINIMUM NUMBER
Bathrooms, bathing facilities, or shower rooms required to be accessible by 4.1 shall comply with 4.23 and shall be on an accessible route....
-
15. Laundry rooms
Laundry rooms 4.32.6 If provided in the facility or at the site, at least one of each type of appliance provided in each laundry area, except that laudry rooms serving covered multifamily...
-
M305.4 Leg Supports
Leg supports shall provide a method of supporting, positioning, and securing the patient’s legs.
-
M301.2 Transfer Surface
A transfer surface shall be provided and shall comply with M301.2.
-
M301.2.3 Size
The size of the transfer surface shall comply with M301.2.3.1 or M301.2.3.2. The size of transfer surfaces shall be measured from center points of their opposing sides.
-
M301.2.3 Size (Section-by-Section Analysis)
The MDE NPRM proposed a transfer surface size for diagnostic equipment used in the supine, prone, or side-lying position of 30 inches wide and 15 inches deep minimum. (proposed...
-
5.2.1 Transfer Surface Size Recommendations for M301
5.2.1 Transfer Surface Size Recommendations for M301 Description: The transfer surface is the part of the diagnostic equipment onto which patients who use mobility devices or aids...
-
5.2.1.1 Transfer Surface Width
5.2.1.1 Transfer Surface Width. The transfer surface should be 28 inches wide minimum for equipment used by patients in a supine, side-lying, or prone position.
-
5.2 Transfer Surface Size for Equipment Used by Patients in Supine, Prone, or Side-Lying Position
5.2 Transfer Surface Size for Equipment Used by Patients in Supine, Prone, or Side-Lying Position.
-
5.2.1 Transfer Surface Size
5.2.1 Transfer Surface Size
-
5.2.1.2 Transfer Surface Depth
5.2.1.2 Transfer Surface Depth. The transfer surface should be 17 inches deep minimum for all equipment used by patients in a supine, side-lying, or prone position with the exception...
-
5.2.1.1 Transfer Surface Width Recommendations for M301
5.2.1.1 Transfer Surface Width Recommendations for M301 The Committee recommends a transfer surface of 28 inches minimum width for equipment used by patients in a supine,...
-
5.2 Transfer Surface Size Recommendations
5.2 Transfer Surface Size Recommendations