Each entrance to a building or facility required to comply with 206.4 shall have at least one door, doorway, or gate complying with 404....
Search Results "Door Swing"
-
11B-206.5.1 Entrances
-
11B-206.5.1 Entrances
Each entrance to a building or facility required to comply with 206.4 shall have at least one door, doorway, or gate complying with 404. ...
-
11B-206.5.1 Entrances
Each entrance to a building or facility required to comply with 206.4 shall have at least one door, doorway, or gate complying with 404....
- DORMA ED900 Low-Energy Swing Door Operator
-
407.3.3 Reopening Device
Elevator doors shall be provided with a reopening device complying with 407.3.3 that shall stop and reopen a car door and hoistway door automatically if the door becomes obstructed by an...
-
407.3.3 Reopening Device
Elevator doors shall be provided with a reopening device complying with 407.3.3 that shall stop and reopen a car door and hoistway door automatically if the door becomes obstructed by an...
-
11B-407.3.3 Reopening device
Elevator doors shall be provided with a reopening device complying with Section 11B-407.3.3 that shall stop and reopen a car door and hoistway door automatically if the door becomes obstructed...
-
11B-407.3.3 Reopening device
Elevator doors shall be provided with a reopening device complying with Section 11B-407.3.3 that shall stop and reopen a car door and hoistway door automatically if the door becomes obstructed...
-
11B-407.3.3 Reopening device
Elevator doors shall be provided with a reopening device complying with Section 11B-407.3.3 that shall stop and reopen a car door and hoistway door automatically if the door becomes obstructed...
-
407.3.3 Reopening Device
Elevator doors shall be provided with a reopening device complying with 407.3.3 that shall stop and reopen a car door and hoistway door automatically if the door becomes obstructed by an...
- ADAEZ Pro Plus Automatic Door Opener Installing Operator Mounting Bracket and Door Arm Pivot Video
- NABCO GT300 & GT8300 Overhead Concealed Low-Energy Swing Door Operator
- Tormax Technologies iMotion® TN 110 In-Floor Swing Door Operator (High and Low Energy)
-
404.2.7 Door and Gate Hardware
404.2.7 Door and Gate Hardware. Handles, pulls, latches, locks, and other operable parts on doors and gates shall comply with 309.4....
-
404.3.1 Clear Width
The minimum clear width for automatic door systems in a doorway shall be based on the clear opening provided by all leaves in the open position....
-
404.3.1 Clear Width
The minimum clear width for automatic door systems in a doorway shall be based on the clear opening provided by all leaves in the open position. [ECTCR UFAS 4.13.5]...
-
404.3.1 Clear Width
The minimum clear width for automatic door systems in a doorway shall be based on the clear opening provided by all leaves in the open position....
-
404.2.7 Door and Gate Hardware
Handles, pulls, latches, locks, and other operable parts on doors and gates shall comply with 309.4....
-
404.2.7 Door and Gate Hardware
Handles, pulls, latches, locks, and other operable parts on doors and gates shall comply with 309.4....
-
Doorways [4.8.4]
Landings must provide the maneuvering clearance at doors required in ADAAG 4.13. ADAAG allows the landing to overlap maneuvering clearances at doors....
- Besam SL500 A02 for sustainable automatic doors
-
Thresholds at Doorways
The 1991 Standards, at section 4.13.8, require the height of thresholds at doorways not to exceed ½ inch and thresholds at exterior sliding doors not to exceed ¾ inch....
-
End-of-Row Stalls
If an out swinging door is provided at an end-of-row stall, maneuvering space of at least 18 inches at the latch side pull side must be provided....
-
H2
Does the door to the toilet room provide at least 32 inches clear passage width when the door is open 90 degrees? [ADA Standards § 4.13.5] Yes No...