Slopes - Examine each of the interior routes described above: ...excluding accessible ramps, do the corridors have running slopes (i.e.: in the direction of travel) not more than 1:20...
Search Results "Curb Ramp"
Commonly Searched Documents
-
B. Slopes
-
§ 38.23(c)(3) Ramp threshold
(3) Ramp threshold. The transition from roadway or sidewalk and the transition from vehicle floor to the ramp may be vertical without edge treatment up to 1/4 inch....
-
Landings [§405.7]
Intermediate landings between runs must be at least 60” wide clear and 60” long clear where ramps change direction (any change from linear)....
-
11B-1003.2.2 Boarding piers at boat launch ramps
Accessible routes serving boarding piers at boat launch ramps shall be permitted to use the exceptions in Section 11B-1003.2.2....
-
Re: 405 Ramps
Gentlemen/Ladies: While the code requires a 60"x 60" clear landing, does it have to be square? Please see attached and advise, thank you.
-
§ 38.159(c)(6) Attachment
When in use for boarding or alighting, the ramp shall be firmly attached to the vehicle so that it is not subject to displacement when loading or unloading a heavy power mobility aid and...
-
11B-1003.2.2 Boarding piers at boat launch ramps
Accessible routes serving boarding piers at boat launch ramps shall be permitted to use the exceptions in Section 11B-1003.2.2. Exceptions: 1. ...
-
11B-1003.2.2 Boarding piers at boat launch ramps
Accessible routes serving boarding piers at boat launch ramps shall be permitted to use the exceptions in Section 11B-1003.2.2. Exceptions: 1....
- GameTime ADA Wide Ramp Attachment 3D
-
Components of Accessible Routes
[See subsections ...]
-
Additional Technical Criteria Considered for Handrails on Ramps
M303.3.3.5 would require handrails to be provided on each side of the ramp when the vertical rise of the ramp exceeds 6 inches....
-
R407.6.4 Change in Direction
Ramps that change direction between runs at landings shall have a clear landing 1.5 m (5.0 ft) minimum by 1.5 m (5.0 ft) minimum....
-
Can ramps be portable or provided after construction as an adaptation?
All required ramps and curb ramps must be permanent and installed at the time of construction or alteration with few exceptions....
-
11B-1008.2.5.1 Ground level
Ramp runs connecting ground level play components shall have a running slope not steeper than 1:16....
-
1008.2.5.1 Ground Level
Ramp runs connecting ground level play components shall have a running slope not steeper than 1:16....
-
1008.2.5.1 Ground Level
Ramp runs connecting ground level play components shall have a running slope not steeper than 1:16....
-
11B-1008.2.5.1 Ground level
Ramp runs connecting ground level play components shall have a running slope not steeper than 1:16....
-
11B-1008.2.5.1 Ground level
Ramp runs connecting ground level play components shall have a running slope not steeper than 1:16....
-
405.2 Slope (Exception 2), 405.6 Rise (Exception)
The running slope of ramp runs must not be steeper than 1:12 and any ramp rise must be 30 inches maximum....
-
11B-608.7 Thresholds
Thresholds in roll-in type shower compartments shall be ½ inch (12.7 mm) high maximum in accordance with Section 11B-303. [2010 ADAS] 608.7 Thresholds. Thresholds in roll-in type...
-
11B-608.7 Thresholds
11B-608.7 Thresholds. Thresholds in roll-in type shower compartments shall be ½ inch (12.7 mm) high maximum in accordance with Section 11B-303. [2010 ADAS] 608.7 Thresholds....
-
11B-608.7 Thresholds
Thresholds in roll-in type shower compartments shall be ½ inch (12.7 mm) high maximum in accordance with Section 11B-303. In transfer type shower compartments, thresholds ½ inch...
-
4.2 Physical Accessibility Barriers and Solutions
Use cones and/or tape and temporary signs to mark additional parking spaces Restripe parking area to include ADAAG required widths for accessible parking spaces No curb...