(a) The minimum clear floor area should be 35 inches (890 mm) by 60 inches (1525 mm). Permanently installed fixtures may overlap this area a maximum of 6 inches (150 mm), if the...
Search Results "Bedside Clearance"
Commonly Searched Documents
- 
    
  
  (1)(a)
  
 - 
    
  
  § 38.123(a)(1)
  
(1) The minimum clear floor area shall be 35 inches by 60 inches. Permanently installed fixtures may overlap this area a maximum of 6 inches, if the lowest portion of the fixture is...
 - Guldmann Excellent Ramp System
 - 
    
  
  604.9.6 Dispensers
  
There shall be a clearance of 1 1/2 inches (38 mm) minimum below the grab bar. Dispensers shall not be of a type that controls delivery or that does not allow continuous paper flow....
 - 
    
  
  604.9.6 Dispensers
  
There shall be a clearance of 1½ inches (38 mm) minimum below the grab bar. Dispensers shall not be of a type that controls delivery or that does not allow continuous paper flow....
 - 
    
  
  11B-604.9.6 Dispensers
  
There shall be a clearance of 1½ inches (38 mm) minimum below the grab bar. Dispensers shall not be of a type that controls delivery or that does not allow continuous paper flow....
 - 
    
  
  11B-604.9.6 Dispensers
  
There shall be a clearance of 1½ inches (38 mm) minimum below the grab bar. Dispensers shall not be of a type that controls delivery or that does not allow continuous paper flow....
 - 
    
  
  11B-604.3.2 Overlap
  
routes, clear floor space and clearances required at other fixtures, and the turning space....
 - 
    
  
  11B-604.9.6 Dispensers
  
There shall be a clearance of 11/2 inches (38 mm) minimum below the grab bar. Dispensers shall not be of a type that controls delivery or that does not allow continuous paper flow....
 - Bobrick Accessibility Video -- Mounting Height and Reach Ranges
 - 
    
  
  T303 Handrails, Stanchions, and Handholds
  
The technical requirements for handrails, stanchions, and handholds include specifications on edges, cross sections, and clearances (i.e., space between gripping surface and adjacent surface...
 - Figure 1005.3.2 Extended Ground or Deck Surface at Fishing Piers and Platforms – Drawing from the U.S. Access Board
 - 
    
  
  11B-604.3.2 Overlap
  
routes, clear floor space and clearances required at other fixtures, and the turning space....
 - 
    
  
  11B-604.3.2 Overlap
  
routes, clear floor space and clearances required at other fixtures, and the turning space....
 - 
    
  
  1016.9 Protruding Objects
  
However, entities should maintain the vertical clearance along outdoor recreation access routes, resting intervals, and passing spaces free from tree branches for 80 inches high minimum...
 - 
    
  
  404.2.4.4 Floor or Ground Surface
  
Floor or ground surface within required maneuvering clearances shall comply with 302. Changes in level are not permitted. EXCEPTIONS: 1....
 - 
    
  
  404.2.4.4 Floor or Ground Surface
  
Floor or ground surface within required maneuvering clearances shall comply with 302. Changes in level are not permitted. EXCEPTIONS: 1....
 - 
    
  
  404.2.4.4 Floor or Ground Surface
  
Floor or ground surface within required maneuvering clearances shall comply with 302. Changes in level are not permitted. EXCEPTIONS: 1....
 - 
    
  
  11B-404.2.4.4 Floor or ground surface
  
Floor or ground surface within required maneuvering clearances shall comply with Section 11B-302. Changes in level are not permitted. Exceptions: 1. ...
 - 
    
  
  Forward Approach
  
Forward Approach Clear floor space is required to the face of the unit; a portion can be provided below the unit where clearance is available for toes/knees....
 - 
    
  
  11B-404.2.4.4 Floor or ground surface
  
Floor or ground surface within required maneuvering clearances shall comply with Section 11B-302. Changes in level are not permitted. Exceptions: 1....
 - 
    
  
  1133A.2, Item 2
  
2. A clear floor space at least 30 inches (762 mm) by 48 inches (1219 mm) that allows either a parallel or forward approach shall be provided at the kitchen sink and all other...
 - 
    
  
  1133A.2 Clear floor space
  
1133A.2 Clear floor space. Clear floor space at kitchens shall comply with the following:
 - 
    
  
  Question 10
  
YES/NO 10. Is the accessible entrance into the building free of obstacles that block the clear wall and floor space needed for opening the door...