These revised requirements reflect incremental changes that were added either because of additional study by the Access Board or in order to harmonize requirements with the model codes....
Search Results "Adult Changing Table"
-
Section 35.150(b)(2) Safe harbor (Section-by-Section Analysis)
-
M305.2 Transfer Supports (Section-by-Section Analysis)
(Significant Changes – Transfer Supports), the Access Board strengthened the transfer support requirements and added additional requirements in the final rule to ensure that supports are...
-
Changes in Level within a Dwelling Unit
For single-story dwelling units and multistory dwelling units, the Guidelines for Requirement 4 are as follows: (1) For single-story dwelling units, the design specifications for changes...
-
Floor or Ground Surfaces: ADA Standard Section 502.4
Section 502.4 covers the current ADA Standards for the floor or ground surfaces of accessible parking spaces.
-
M301.4 Lift Compatibility (Section-by-Section Analysis)
In the final rule the Access Board has made an editorial change to clarify the type of lift; namely portable patient lift, and a change to clarify that the clearance provisions only apply...
-
Associated Constructed Feature
Examples include camp shelters, pit toilets, fire rings, picnic tables, and tent pads. Refer to FSORAG for the technical provisions for associated constructed features....
-
M301.3.2 Leg Supports
Where stirrups are provided, leg supports shall also be provided and shall comply with M305.4.
-
M301.3.2 Stirrups
Where stirrups are provided, they shall provide a method of supporting, positioning, and securing the patient’s legs.
-
305.2 Floor or Ground Surfaces
Changes in level are not permitted. EXCEPTION: Slopes not steeper than 1:48 shall be permitted....
-
305.2 Floor or Ground Surfaces
Changes in level are not permitted. EXCEPTION: Slopes not steeper than 1:48 shall be permitted....
-
11B-305.2 Floor or ground surfaces
Changes in level are not permitted. Exception: Slopes not steeper than 1:48 shall be permitted...
-
11B-305.2 Floor or ground surfaces
Changes in level are not permitted. Exception: Slopes not steeper than 1:48 shall be permitted....
-
305.2 Floor or Ground Surfaces
Changes in level are not permitted. [ECTCR UFAS 4.2.4.3] EXCEPTION: Slopes not steeper than 1:48 shall be permitted....
-
305.2 Floor or Ground Surfaces
Changes in level are not permitted. EXCEPTION: Slopes not steeper than 1:48 shall be permitted....
- Ronick Matting Systems BaseMat 300 Entrance Floor Mat
-
36 CFR Part 1195 Standards for Accessible Medical Diagnostic Equipment
The standards for medical diagnostic equipment (MDE Standards) contain minimum technical criteria to ensure that medical diagnostic equipment, including but not limited to, examination tables...
-
M301.2.2 Sunset Provision (Section-by-Section Analysis)
(Significant Changes – Transfer Surface Adjustability), this is a new provision that was added to the final rule in conjunction with the new requirement of a low height range in M301.2.1...
-
M305.2.2 Length (Section-by-Section Analysis)
imaging equipment with transfer surfaces less than or equal to 24 inches deep, the Committee recommended requiring a transfer support to extend horizontally along the side of the patient table...
-
M305.2.8 Fittings (Section-by-Section Analysis)
Specifically, one commenter (manufacturer) asserted that the technical criteria from the 2004 ADA and ABA Accessibility Guidelines for grab bars in bathrooms should not be applied to exam tables...
-
M301.3.1 Transfer Supports
Transfer surfaces required by M301.2 shall provide transfer supports and shall comply with M305.2.
-
M305.5 Head and Back Support
Where the diagnostic equipment is used in a reclined position, head and back support shall be provided. Where the incline of the back support can be modified while in use, head and...
-
M301.3 Supports
Transfer supports, leg supports, and reclining surfaces shall comply with M301.3.
-
M301.3.3 Head and Back Support
Where the diagnostic equipment is used in a reclined position, head and back support shall be provided and shall comply with M305.5.
-
M301.3.3 Head and Back Support (Section-by-Section Analysis)
In the MDE NPRM the Access Board proposed to place the requirements for head and back support for diagnostic equipment used by patients in the supine, prone, or side-lying position...