Hand operated flush controls shall comply with Section 11B-309 except they shall be located 44 inches (1118 mm) maximum above the floor....
Search Results "Clear Floor Area"
-
11B-604.6 Flush controls
-
M301.2.1, M302.2.1 Transfer Height
Transfer Height Proposed requirement: The height of the transfer surface during patient transfer shall be 17 inches (430 mm) minimum and 19 inches (485 mm) maximum measured from the floor...
-
11B-404.2.7 Door and gate hardware
Operable parts of such hardware shall be 34 inches (864 mm) minimum and 44 inches (1118 mm) maximum above the finish floor or ground....
-
11B-404.2.7 Door and gate hardware
Operable parts of such hardware shall be 34 inches (864 mm) minimum and 44 inches (1118 mm) maximum above the finish floor or ground....
-
Vertical Access to Mezzanines
While elevators, where provided, must serve all stories, including mezzanines where provided, ADAAG has not been clear on whether some form of vertical access is nonetheless required to...
-
Conclusion
There is a clear distinction between 49 CFR § 37.43(a)(1) and (a)(2)....
-
O. Accessible Portable Toilets
Accessible portable toilets should similar features to a standard accessible toilet stall including an accessible door, side and rear grab bar, clear space next to the toilet, and maneuvering...
-
§35.172 Resolution of complaints (Section-by-Section Analysis)
The Committee Reports make clear that Congress intended to provide a private right of action with the full panoply of remedies for individual victims of discrimination....
-
New Construction. (Section-by-Section Analysis)
The NPRM did not expressly propose that new construction of correctional and detention facilities shall comply with the proposed standards because the Department assumed it would be clear...
-
Examples of making a program accessible are:
It is not necessary to remove physical barriers at the inaccessible campus, if the two campuses offer the same courses, have the same hours, and serve the same geographic area....
-
Technical Memorandum TM 2013-11 Benches
Dressing, Fitting, and Locker Rooms TAS 803.4 Holding Cells and Housing Cells TAS 807.2.2 Fixed or built-in benches and other types of fixed seating provided in assembly areas...
-
Notifying the Access Board When an Entire Trail or Beach Access Route is Exempted [F204.4.1]
forms are in the appendix of this guide and are also available on the Access Board’s Web site at www.access-board.gov/guidelines-and -standards/recreation-facilities/outdoor-developed-areas...
-
Vertical Clearance [§307.4]
Barriers at Circulation Areas with Reduced Vertical Clearance Recommendation: A minimum height is not specified for barriers demarcating areas with less than 80” of vertical...
-
When an addition increases the number of stories or square footage beyond the maximum permitted by the exception, is an accessible route between stories required?
Also, if the addition includes a primary function area, an accessible path of travel to the primary function area is required, including where it involves travel between stories or levels...
-
Required Compliance [§209]
Compliance is required only where areas are specifically designed or designated for passenger loading, such as those at airports, many hotels, and convention centers....
-
11B-202.2 Additions
Each addition that affects or could affect the usability of or access to an area containing a primary function shall comply with 202.4. ...
-
Rail Station Signs: ADA Standard Section 810.6
By scanning an area, the person will hear the sign. This means that signs can be placed well out of reach of braille readers, even on parapet walls and on walls beyond barriers....
-
11B-405.9 Edge protection
Edge protection shall not be required on the sides of ramp landings having a vertical drop-off of ½ inch (12.7 mm) maximum within 10 inches (254 mm) horizontally of the minimum landing area...
-
11B-209.2.2 Bus loading zones
In bus loading zones restricted to use by designated or specified public transportation vehicles, each bus bay, bus stop, or other area designated for lift or ramp deployment shall comply...
-
11B-209.2.2 Bus loading zones
In bus loading zones restricted to use by designated or specified public transportation vehicles, each bus bay, bus stop, or other area designated for lift or ramp deployment shall comply...
-
11B-405.9 Edge protection
Edge protection shall not be required on the sides of ramp landings having a vertical drop-off of ½ inch (12.7 mm) maximum within 10 inches (254 mm) horizontally of the minimum landing area...
-
Rear Wall: ADA Standard Section 604.5.2
Section 604.5.2 covers the current ADA Standards for rear wall grab bars that are used for water closets.
-
11B-802.4.2 Identification
If there is no ticket office, the functional equivalent would be in the lobby or at the entrance to the assembly area in a conspicuous location. ◼...