The slope of the resting area in all directions shall be 1:48 maximum. ETA Editor's Note CBC requirement 11B-403.7 is not present in the 2010 ADA Standards....
Search Results "Slope"
Commonly Searched Documents
- 
    
  
  11B-403.7 Continuous gradient
  
- 
    
  
  1014.3 Floor
  This section requires the floor surface within camp shelters to be firm and stable and to slope not steeper than 1:48 in any direction.... 
- 
    
  
  11B-233.3.1.2.6.3 Test number two, site analysis test
  Calculate the percentage of the total buildable area of the undisturbed site with a natural grade less than 10 percent slope.... 
- 
    
  
  11B-402.2 Components
  Accessible routes shall consist of one or more of the following components: walking surfaces with a running slope not steeper than 1:20, doorways, ramps, curb ramps excluding the flared... 
- 
    
  
  11B-411.2.1.3.4 Position
  Keypads or buttons shall slope away from the user at 15 to 25 degrees from the vertical plane.... 
- 
    
  
  11B-411.2.1.3.4 Position
  Keypads or buttons shall slope away from the user at 15 to 25 degrees from the vertical plane.... 
- 
    
  
  Passing Spaces [1017.4]
  Nominally planar means on the same nominal table surface (same nominal geometric surface plane) and the slopes of the table surface correspond to the running slope and cross slope of the... 
- 
    
  
  1131A.2 Changes greater than ½ inch
  Changes in level greater than ½ inch (12.7 mm) shall be made by means of a sloped surface not greater than 1 unit vertical in 20 units horizontal (5-percent slope), or a ramp, elevator or... 
- 
    
  
  1131A.2 Changes greater than ½ inch
  Changes in level greater than ½ inch (12.7 mm) shall be made by means of a sloped surface not greater than 1 unit vertical in 20 units horizontal (5-percent slope), or a ramp, elevator or... 
- 
    
  
  1131A.1 Changes in level not exceeding ½ inch
  When changes in level do occur, they shall be beveled with a slope no greater than 1 unit vertical in 2 units horizontal (50-percent slope).... 
- 
    
  
  1131A.1 Changes in level not exceeding ½ inch
  When changes in level do occur, they shall be beveled with a slope no greater than 1 unit vertical in 2 units horizontal (50-percent slope).... 
- 
    
  
  4. COMMON PATH OF TRAVEL ITEMS
  Public telephones serving the area of alteration • Exterior or interior signs along the path of travel • Accessible route components • Walking surfaces dimensions • Running slope... 
- 
    
  
  Transition Plates
  Transition Plates Transition plates are sloping pedestrian walking surfaces located at the end of a gangway.... 
- 
    
  
  Maneuvering Space Where Ramps are Provided
  The space must have a slope no steeper than 1:48 in all directions. ... 
- 
    
  
  Transition Plates
  Transition Plates Transition plates are sloping pedestrian walking surfaces located at the end of a gangway.... 
- 
    
  
  505.1 General
  Handrails are not required on walking surfaces with running slopes less than 1:20.... 
- 
    
  
  505.1 General
  Handrails are not required on walking surfaces with running slopes less than 1:20.... 
- 
    
  
  704.11.1 Parapet construction
  Where the roof slopes toward a parapet at a slope greater than two units vertical in 12 units horizontal (16.7-percent slope), the parapet shall extend to the same height as any portion... 
- 
    
  
  11B-505.1 General
  Handrails are not required on walking surfaces with running slopes less than 1:20.... 
- 
    
  
  1018.1 General
  The technical requirements address connections (1018.2); surface (1018.3); clear width (1018.4); obstacles (1018.5); openings (1018.6); slopes, including running slope (1018.7.1) and cross... 
- 
    
  
  Beveled: ADA Standard Section 303.3
  Section 303.3 covers the current ADA Standards for beveled level changes. 
- 
    
  
  1131A.2 Changes greater than ½ inch
  Changes in level greater than ½ inch (12.7 mm) shall be made by means of a sloped surface not greater than 1 unit vertical in 20 units horizontal (5-percent slope), or a ramp, elevator or... 
- 
    
  
  1131A.1 Changes in level not exceeding ½ inch
  When changes in level do occur, they shall be beveled with a slope no greater than 1 unit vertical in 2 units horizontal (50-percent slope).... 
- 
    
  
  Attachment I: Program Access in Existing Facilities
  Attachment I: Program Access in Existing Facilities 