Signs required by Chapter 10, Section 1009.10 to provide directions to accessible means of egress shall comply with Section 11B-703.5.
Search Results "Signage Height"
Commonly Searched Documents
- 
    
  
  11B-216.4.3 Directional signs
  
- 
    
  
  International Symbol of Accessibility: ADA Standard Section 703.7.2.1
  The International Symbol of Accessibility shall comply with Figure 703.7.2.1. 
- 
    
  
  Rail Station Signs: ADA Standard Section 810.6
  Rail station signs shall comply with 810.6. EXCEPTION. Signs shall not be required to comply with 810.6.1 and 810.6.2 where audible signs are remotely transmitted to hand-held... 
- 
    
  
  11B-812.8.7 Location
  Required identification signs shall be visible from the EVCS it serves. Signs shall be permanently posted either immediately adjacent to the vehicle space or within the projected... 
- 
    
  
  11B-810.6 Rail station signs
  Rail station signs shall comply with Section 11B-810.6. Exception: Signs shall not be required to comply with Sections 11B-810.6.1 and 11B-810.6.2 where audible signs are remotely... 
- 
    
  
  11B-502.8.1 Size
  The additional sign shall not be less than 17 inches (432 mm) wide by 22 inches (559 mm) high. 
- 
    
  
  11B-812.8.4 Ambulatory
  Ambulatory EVCS shall not be required to be identified by an ISA. 
- 
    
  
  11B-812.8.6 Finish and size
  Identification signs shall be reflectorized with a minimum area of 70 square inches (45161 mm2). 
- 
    
  
  11B-502.8 Additional signs
  An additional sign shall be posted either; 1) in a conspicuous place at each entrance to an off-street parking facility or 2) immediately adjacent to on-site accessible parking and... 
- 
    
  
  11B-703.6.1 Pictogram field
  Pictograms shall have a field height of 6 inches (152 mm) minimum. Characters and Braille shall not be located in the pictogram field. Advisory 11B-703.6.1 Pictogram field.... 
- 
    
  
  11B-703.6.1 Pictogram field
  Pictograms shall have a field height of 6 inches (152 mm) minimum. Characters and Braille shall not be located in the pictogram field. Advisory 11B-703.6.1 Pictogram field.... 
- 
    
  
  1005.2.1 Height
  1005.2.1 Height. At least 25 percent of the railings, guards, or handrails shall be 34 inches (865 mm) maximum above the ground or deck surface.... 
- 
    
  
  11B-602.4 Spout height
  Spout outlets shall be 36 inches (914 mm) maximum above the finish floor or ground. 
- 
    
  
  11B-602.4 Spout height
  Spout outlets shall be 36 inches (914 mm) maximum above the finish floor or ground. 
- 
    
  
  11B-703.6.1 Pictogram field
  Pictograms shall have a field height of 6 inches (152 mm) minimum. Characters and Braille shall not be located in the pictogram field. Advisory 11B-703.6.1 Pictogram field. ... 
- Smith System Husky Square Activity Table
- 
    
  
  4.7.9.3 Height
  The counter or rim of the sink shall be no more than 34 inches (865 mm) above the floor or ground. Water spouts must be 28 inches (710 mm) minimum and 36 inches (915 mm) maximum... 
- 
    
  
  11B-216.8 Toilet rooms and bathing rooms
  Entrances to toilet rooms and bathing rooms shall be identified by a geometric symbol complying with Section 11B-703.7.2.6. Where existing toilet rooms or bathing rooms do not comply... 
- Boost Your Business - Chapter 11 - Stairs
- 
    
  
  Signs [ADA Standards §216, §703]
  Visual criteria address the height, style, proportion, and spacing of characters, as well as finish and contrast, line spacing, and other features (§703.5).... 
- ADA Sign Depot Wheelchair Accessible Restroom Sign with Directional Arrow - Tactile Text, Symbols, and Grade 2 Braille
- 
    
  
  National Network of ADA Centers
  of a low height transfer number.... 