Knee clearance shall be provided at a depth of 11 inches (280 mm) minimum and 25 inches (635 mm) maximum at 9 inches (230 mm) above the floor and at a depth of 8 inches (205 mm)...
Search Results "Medical Exam"
-
M303.2.4.2 Knee Clearance
-
M303.1 General
Diagnostic equipment used by patients seated in a wheelchair shall comply with M303.
-
United States of America v. Genesis Healthcare System - Settlement Agreement
SETTLEMENT AGREEMENT BETWEEN THE UNITED STATES OF AMERICA AND GENESIS HEALTHCARE SYSTEM UNDER THE AMERICANS WITH DISABILITIES ACT Press Release
-
6.1(4)(a)
(a) When patient bedrooms are being added or altered as part of a planned renovation of an entire wing, a department, or other discrete area of an existing medical facility, a percentage...
-
11B-206 Accessible routes
Accessible routes shall be provided in accordance with Section 11B-206 and shall comply with Division 4. 11B-206.4.10 Medical care and long-term care facilities....
-
5.8.1.2.1 Ramped Entry Slope Recommendations
The space constraints affect the desirability of accessible scales since space is often expensive and tight in many medical facilities....
-
2. a. i. Accessible parking
Accessible Parking vi “A greater number of accessible parking spaces is required at facilities providing medical care and other services for persons with mobility impairments....
-
F223.1 General
In licensed medical care facilities and licensed long-term care facilities where the period of stay exceeds twenty-four hours, patient or resident sleeping rooms shall be provided in accordance...
-
Care Management/Care Coordination
Medical diagnoses and history S.8.1.f....
-
11B-805 Medical care and long-term care facilities
SECTIONS 11B-805 Medical care and long-term care facilities 11B-805.2 Patient bedrooms and resident sleeping rooms....
-
223.1 General
Medical care facilities shall comply with the provisions applicable to medical care facilities, including, but not limited to, sections 223 and 805....
-
Section 36.309 Examinations and Courses (Preamble, Section-by-Section Analysis)
Examinations covered by this section would include a bar exam or the Scholastic Aptitude Test prepared by the Educational Testing Service....
-
Sec.36.303(e) Closed caption decoders
(e) Closed caption decoders. Places of lodging that provide televisions in five or more guest rooms and hospitals that provide televisions for patient use shall provide, upon...
-
M303.3.3.3 Clear Width
The clear width of ramp runs shall be 36 inches (915 mm) minimum.
-
M303.2.4.2 Other Equipment
Wheelchair spaces beneath diagnostic equipment other than breast platforms shall comply with M303.2.4.2.
-
11B-805.2 Patient bedrooms and resident sleeping rooms
Patient bedrooms and resident sleeping rooms required to provide mobility features shall comply with Section 11B-805.2. ETA Editor's Note According to the Office of...
-
M303.3.3.1 Running Slope
Ramp runs shall have a running slope not steeper than 1:12. EXCEPTION: A running slope not steeper than 1:8 shall be permitted for ramp runs with a maximum height of 2 ½ inches...
-
M303.3.3.4 Edge Protection
Ramps with drop offs ½ inch (13 mm) or greater shall provide edge protection 2 inches (50 mm) high minimum on each side with a drop off.
-
M303.3.3.5 Handrails
Ramps with a rise greater than 6 inches (150 mm) shall provide handrails on both sides.
-
M303.2.6 Edge Protection (Section-by-Section Analysis)
The MDE NPRM proposed edge protection on the ramps leading up to the raised platform (proposed M303.3.3.4), but did not require edge protection on the raised platforms themselves....
-
M301 Diagnostic Equipment used by Patients in a Supine, Prone, or Side-lying Position (Section-by-Section Analysis)
M301 in the final rule establishes the technical criteria for diagnostic equipment used by patients in a supine, prone, or side-lying position such as, examination tables, imaging...
-
5.8.1.1 Clear Platform Size Recommendation
5.8.1.1 Clear Platform Size Recommendation The Committee recommends a platform size with a minimum clear width of 32 inches and a minimum clear length of 40 inches. Rationale...
-
5.8.1.1 Clear Platform Size
5.8.1.1 Clear Platform Size. The platform should be a minimum clear width of 32-inches and a minimum clear length of 40-inches.
-
§ 36.303(e) Closed caption decoders