approach to an element and the side reach is unobstructed, the high side reach shall be 48 inches (1219 mm) maximum and the low side reach shall be 15 inches (381 mm) minimum above the finish...
Search Results "Finish"
-
11B-308.3.1 Unobstructed
-
608.3 Grab Bars
Where multiple grab bars are used, required horizontal grab bars shall be installed at the same height above the finish floor. EXCEPTIONS: 1....
-
20.1 Q. If a covered multifamily dwelling has an individual, private garage which is attached to and serves only that dwelling, does the garage have to be accessible in terms of width and length?
Because such individual garages attached to and serving only one covered multifamily dwelling typically are not finished living space, the garage is not required to be accessible in terms...
-
608.3 Grab Bars
Where multiple grab bars are used, required horizontal grab bars shall be installed at the same height above the finish floor. EXCEPTIONS: 1....
-
11B-805 Medical care and long-term care facilities
to Section 11B-306.3.3, Exception 1 which states: "At lavatories required to be accessible by Section 11B-213.3.4, the knee clearance shall be 27 inches (686 mm) high minimum above the finish...
-
Additional Design Specifications for Requirement 1
Finally, the Guidelines provide that if the slope of the finished grade between covered multifamily dwellings and a public or common use facility exceeds 8.33%, or where other physical barriers...
-
11B-610.3 Shower compartment seats
The top of the seat shall be 17 inches (432 mm) minimum and 19 inches (483 mm) maximum above the bathroom finish floor....
- SLOPE Waste Receptacles
-
704.4.1 Height
When in use, the touch surface of TTY keypads shall be 34 inches (865 mm) minimum above the finish floor....
-
STORY
If the finished floor level directly above a basement or unused under-floor space is more than six feet (1829 mm) above grade for more than 50 percent of the total perimeter or is more than...
-
608.3 Grab Bars
Where multiple grab bars are used, required horizontal grab bars shall be installed at the same height above the finish floor....
-
704.4.1 Height
When in use, the touch surface of TTY keypads shall be 34 inches (865 mm) minimum above the finish floor....
-
610.3 Shower Compartment Seats
The top of the seat shall be 17 inches (430 mm) minimum and 19 inches (485 mm) maximum above the bathroom finish floor. Seats shall comply with 610.3.1 or 610.3.2....
-
307.2 Protrusion Limits
Objects with leading edges more than 27 inches (685 mm) and not more than 80 inches (2030 mm) above the finish floor or ground shall protrude 4 inches (100 mm) maximum horizontally into...
-
Facility
The tops of dining surfaces and work surfaces shall be 28 inches minimum and 34 inches maximum above the finish floor or ground....
-
Effective Communication
Staff and county officials must take the time to listen to N.M, not interrupt him or finish his sentences....
-
704.4.1 Height
When in use, the touch surface of TTY keypads shall be 34 inches (865 mm) minimum above the finish floor....
-
Bathroom Accommodating Reduced Ambulatory Mobility
between the bathtub and toilet (this is actually fun to use) – reinforcement less than $50 Chromatherapy bathtub for relaxation FSC certified maple floor with slip-resistant finish...
-
Kitchen Cabinets
(above finished floor) wall-mounted cabinets and counters for tall people....
-
Door and Gate Surfaces [§404.2.10]
These requirements do not apply to: Sliding doors Doors and gates that do not extend to within 10” of the finish floor or ground Existing doors or gates with kick...
-
Error/Omission: The shape of the door hardware requires tight grasping, pinching, and twisting of the wrist to use.
Hardware required for accessible door passage shall be mounted no higher than 48 in (1220 mm) above finished floor....
-
STORY
If the finished floor level directly above a basement or unused under-floor space is more than six feet (1829 mm) above grade for more than 50 percent of the total perimeter or is more than...
-
11B-307.2 Protrusion limits
Objects with leading edges more than 27 inches (686 mm) and not more than 80 inches (2032 mm) above the finish floor or ground shall protrude 4 inches (102 mm) maximum horizontally into...