BTX systems have been installed in homes across the world for homeowners seeking a new edge on technology, increased security and light control, or an easier way to open and close their...
Search Results "Control End Wall"
Commonly Searched Documents
- BTX Intelligent Fashion Tumo Programming Reverse Motor Direction
-
608.5.2 Standard Roll-In Type Shower Compartments
In standard roll-in type shower compartments, the controls, faucets, and shower spray unit shall be located above the grab bar, but no higher than 48 inches (1220 mm) above the shower floor...
-
f-v
Are the controls and operating mechanisms mounted no more than 54 inches above the floor for a side reach or 48 inches for a forward reach?...
- Door King Inc. Proximity Card Readers
- Sargent Wall and Frame Switch Interface for Door Operators
-
R209 Accessible Pedestrian Signals and Pedestrian Pushbuttons (Section-by-Section Analysis)
For existing pedestrian signals, the proposed guidelines require accessible pedestrian signals and pedestrian pushbuttons to be provided when the signal controller and software are altered...
-
11B-1009.2.7 Operation
Controls and operating mechanisms shall be unobstructed when the lift is in use and shall comply with Section 11B-309.4....
-
11B-1009.2.7 Operation
Controls and operating mechanisms shall be unobstructed when the lift is in use and shall comply with Section 11B-309.4....
-
K. Operable Parts
Are the drapery wands and controls on fixed lamps and HVAC units easily operable with one hand, without tight grasping, pinching or twisting of the wrist, since many persons with disabilities...
- BTX Intelligent Fashion Tumo Drapery System Installation Video
-
11B-1009.2.7 Operation
Controls and operating mechanisms shall be unobstructed when the lift is in use and shall comply with Section 11B-309.4....
-
11B-608.5.3 Alternate roll-in type shower compartments
In alternate roll-in type shower compartments, the controls, faucets, and shower spray unit shall be located on the side wall of the compartment adjacent to the 16 inches (406 mm) minimum...
-
§ 38.107(a)(5)
(5) Doorways on the end of the enclosure, opposite the water closet, shall have a minimum clear opening width of 32 inches....
-
608.5.3 Alternate Roll-In Type Shower Compartments
Where a seat is provided, the controls, faucets, and shower spray unit shall be located on the side wall adjacent to the seat 27 inches (685 mm) maximum from the side wall behind the seat...
-
608.5.3 Alternate Roll-In Type Shower Compartments
Where a seat is provided, the controls, faucets, and shower spray unit shall be located on the side wall adjacent to the seat 27 inches (685 mm) maximum from the side wall behind the seat...
-
407.1 General (Section-by-Section Analysis)
407.1 General (Section-by-Section Analysis) This section addresses accessibility features of operable parts—such as keys and controls—when part of the user interface is hardware....
-
11B-608.5.3 Alternate roll-in type shower compartments
In alternate roll-in type shower compartments, operable parts of controls and faucets shall be installed on the side wall of the compartment adjacent to the seat wall 19 inches (483 mm)...
-
1134A.8, Item 7
Lavatory faucet controls. Faucet controls and operation mechanisms shall be operable with one hand and shall not require tight grasping, pinching or twisting of the wrist....
-
608.5.3 Alternate Roll-In Type Shower Compartments
Where a seat is provided, the controls, faucets, and shower spray unit shall be located on the side wall adjacent to the seat 27 inches (685 mm) maximum from the side wall behind the seat...
-
27.1 Q. Do the Guidelines set any requirements for the type or location of bathtub controls?
In that case, while the type of control is not specified, the control must be located as shown in Figure 8 of the Guidelines. ...
-
11B-407.4.7.2 Keypads
ETA Editor's Note The preceding CBC requirements for elevator controls at 11B-407.4.6 and 11B-407.4.7 are more stringent than those of 2010 ADA Standards....
-
309.3 Height
309.3 Height. Operable parts shall be placed within one or more of the reach ranges specified in 308.
-
11B-309.3 Height
Operable parts shall be placed within one or more of the reach ranges specified in Section 11B-308.
-
M307.3 Operation
Operable parts shall be operable with one hand and shall not require tight grasping, pinching, or twisting of the wrist.