Risers shall be permitted to slope under the tread at an angle of 30 degrees maximum from vertical....
Search Results "Building Permit"
-
11B-504.5 Nosings
-
Sec. 469.102(d)
(d) A public official of a political subdivision who is legally authorized to issue building construction permits may not accept an application for a building construction permit for a building...
-
11B-233.3.1.2.4 Multi-story residential dwelling units in buildings with one or more elevators
In elevator buildings, public housing facilities with multi-story residential dwelling units shall comply with the following: The primary entry of the multi-story residential...
-
Do the exceptions for accessible routes between stories apply to facilities that are only partially occupied by entities not permitted the exception, such as health care facility or shopping center?
In mixed use facilities that otherwise qualify for this exception, an accessible route is required to serve each story containing occupancies not permitted the exception....
-
4.1.7(2)(a) Alterations to Qualified Historic Buildings and Facilities Subject to Section 106 of the National Historic Preservation Act
(a) Alterations to Qualified Historic Buildings and Facilities Subject to Section 106 of the National Historic Preservation Act:...
-
Are bollards, poles, columns, or other elements permitted within the marked area of access aisles?
No elements, including bollards, columns, or poles, can encroach into the defined area of access aisles. (The width of spaces and aisles is measured to the centerline of markings but...
-
11B-207.1 General
Means of egress shall comply with section 1003.2.13 of the International Building Code (2000 edition and 2001 Supplement) or section 1007 of the International Building Code (2003 edition...
-
§ 36.406(a)(1)
(1) New construction and alterations subject to §§ 36.401 or 36.402 shall comply with the 1991 Standards if the date when the last application for a building permit or permit extension is...
-
§ 36.406(a)(3)
(3) New construction and alterations subject to §§ 36.401 or 36.402 shall comply with the 2010 Standards if the date when the last application for a building permit or permit extension is...
-
Sec. 469.102(c)
(c) The owner of the building or facility may not allow an application to be filed with a local governmental entity for a building construction permit related to the plans and specifications...
-
Current Accessibility Guidelines That Apply to the Forest Service
Forest Service drinking fountains, toilet facilities, parking lots and spaces, cabins, and administrative buildings are among the components covered by ABAAS....
-
22. Q. We are building a new prison. Do we need to make it accessible?
All new buildings must be made fully accessible to, and usable by, individuals with disabilities....
-
1.9.1.1.5
1.9.1.1.5 With respect to buildings, structures, sidewalks, curbs and related facilities not requiring a building permit, building standards published in the California Building Standards...
-
11B-206.6 Elevators
In a building or facility permitted to use the exceptions to Section 11B-206.2.3 _|Accessible Routes; Multi-Story Buildings and Facilities|_ or permitted by Section 11B-206.7 to use a platform...
-
11B-206.6 Elevators
In a building or facility permitted to use the exceptions to Section 11B-206.2.3 _|Accessible Routes; Multi-Story Buildings and Facilities|_ or permitted by Section 11B-206.7 to use a platform...
-
11B-211.2 Minimum number
Exception: Where a single drinking fountain complies with Sections 11B-602.1 through 11B-602.9, it shall be permitted to be substituted for two separate drinking fountains....
-
11B-211.2 Minimum number
Exception: Where a single drinking fountain complies with Sections 11B-602.1 through 11B-602.9, it shall be permitted to be substituted for two separate drinking fountains....
- Hager Companies 5100 Series - Heavy Duty Surface Door Closer
-
§ 36.406(a)(2)
(2) New construction and alterations subject to §§ 36.401 or 36.402 shall comply either with the 1991 Standards or with the 2010 Standards if the date when the last application for a building...
-
Door Swing: ADA Standard Section 603.2.3
Section 603.2.3 covers the current ADA Standards for door swings at clear floor space and clearances at fixtures in toilet and bathing rooms.
-
[A] 111.2 Certificate issued
, the building official shall issue a certificate of occupancy that contains the following: The building permit number....
-
111.2 Certificate issued
, the building official shall issue a certificate of occupancy that contains the following: The building permit number....
-
Issue 11: What environmental and perceptual data on natural/daylighting are available from buildings with low vision occupants?
We had 50 to 70 [responses from employees] in [each of] the buildings. Question by [Participant]: Were these GSA-owned buildings or were these the leases?...
-
[A] 111.2 Certificate issued
The building permit number. 2. The address of the structure. 3. The name and address of the owner. 4. ...