[56 FR 45621, Sept. 6, 1991, as amended at 58 FR 63101, Nov. 30, 1993; 61 FR 25416, May 21, 1996]
Search Results "Alternate Door"
Commonly Searched Documents
-
§ 37.7 Standards for accessible vehicles
-
1010.1.7 Thresholds
or landing for other doors....
-
11B-407.4.1 Car dimensions
Inside dimensions of elevator cars and clear width of elevator doors shall comply with Table 11B-407.4.1....
- ADAEZ Pro Plus Automatic Door Opener Quick Tip Offset Pivot Application Video
-
Guest Rooms with Mobility Features: ADA Standard Section 224.2
Section 224.2 covers scoping requirements in the current ADA Standards for transient lodging guest rooms with mobility features.
-
11B-809.10.6.1 Size
When one or more shower stalls are provided within the same dwelling unit, as least one shower stall shall comply with one of the following: A transfer type shower...
- Mockett DH3/BB Square Door Handle Installation Video
-
Plan 2B: 13-Foot Wide Accessible Guest Room
Features include an alternate roll-in shower with a seat, comparable vanity, wardrobe, and door connecting to adjacent guest room. Furnishings include two beds. ...
-
Question 19
Are the entrances to accessible public restrooms and fitting rooms free of obstacles that block the clear wall and floor space needed for opening the door (between 18 and 42 inches on the...
-
Doorways: ADA Standard Section 405.7.5
Section 405.7.5 covers the current ADA Standards for doorway maneuvering clearance at ramp landings.
- ADAEZ Pro Plus Automatic Door Opener Quick Tip Operator Mounting Bracket Variations Video
-
11B-604.8.1.1.1 Maneuvering space with in-swinging door
In a wheelchair accessible compartment with an in-swinging door, a minimum 60 inches (1524 mm) wide by 36 inches (914 mm) deep maneuvering space shall be provided in front of the clearance...
-
11B-604.8.1.1.1 Maneuvering space with in-swinging door
In a wheelchair accessible compartment with an in-swinging door, a minimum 60 inches (1524 mm) wide by 36 inches (914 mm) deep maneuvering space shall be provided in front of the clearance...
- LaCantina Doors
-
SECTION 1010 DOORS, GATES AND TURNSTILES
[DSA-AC] In addition to the requirements of this section, means of egress, which provide access to, or egress from, buildings or facilities where accessibility is required for...
-
SECTION 1010 DOORS, GATES AND TURNSTILES
[DSA-AC] In addition to the requirements of this section, means of egress, which provide access to, or egress from, buildings or facilities where accessibility is required for...
-
19.1 Q. If a sliding door track has a threshold of 3/4, does this trigger requirements for ramps?
The Guidelines at Requirement 4 provide that thresholds at doors, including sliding door tracks, may be no higher than 3/4 and must be beveled with a slope no greater than 1:2....
-
H3
[ADA Standards § 4.13.9] Yes No If No, can the door be propped open without compromising privacy, or can the hardware be modified by adding new accessible hardware, or adapting...
-
Elevator Door Requirements [§407.3]
Elevator Door Requirements [§407.3]...
-
4.8.4(4)
(4) If a doorway is located at a landing, then the area in front of the doorway shall comply with 4.13.6.
-
Controls [§404.3.5]
Controls [§404.3.5] Door and gate controls must be compliant as operable parts (operable with one hand and without tight grasping, pinching, twisting of the wrist, or more than 5 lbf)...
-
4.10.9 Floor Plan of Elevator Cars
Acceptable door opening and inside dimensions shall be as shown in Fig. 22....
-
4.10.9 FLOOR PLAN OF ELEVATOR CARS
Acceptable door opening and inside dimensions shall be as shown in Fig. 22....
-
Re: 404.2.4.3 Recessed Doors and Gates
Notice that the text does not match the figure for a push approach door. This may be an error in the Standards, but since the text governs, it exceeds the illustrated requirement. ...