Where provided thresholds shall be 2 inches (51 mm) maximum in height and have a beveled or sloped angle not exceeding 1 unit vertical in 2 units horizontal (26.6 degrees from the horizontal...
Search Results "Horizontal Position"
-
11B-809.10.6.5 Thresholds
-
RECOMMENDATIONS
The former includes the impact of current guidelines and alternative designs on: safety and injury prevention; proper positioning of care recipients and care providers; stress reduction,...
-
Re: American Specialties 9014 Surface Mounted Horizontal Baby Changing Station
Rejected this after installation. The design of the hand hold is completely sloped at about 45 degrees. My fingers slipped off unless I applied tremendous pinching force to operate....
-
11B-1002.4.3 Gaps
Floors of amusement rides with wheelchair spaces and floors of load and unload areas shall be coordinated so that, when amusement rides are at rest in the load and unload position, the vertical...
-
1002.4.3 Gaps
Floors of amusement rides with wheelchair spaces and floors of load and unload areas shall be coordinated so that, when amusement rides are at rest in the load and unload position, the vertical...
-
1002.4.3 Gaps
Floors of amusement rides with wheelchair spaces and floors of load and unload areas shall be coordinated so that, when amusement rides are at rest in the load and unload position, the...
-
11B-1002.4.3 Gaps
Floors of amusement rides with wheelchair spaces and floors of load and unload areas shall be coordinated so that, when amusement rides are at rest in the load and unload position, the vertical...
-
11B-1002.4.3 Gaps
Floors of amusement rides with wheelchair spaces and floors of load and unload areas shall be coordinated so that, when amusement rides are at rest in the load and unload position, the vertical...
-
Web Accessibility 101: Screen Magnification & Reflow in Acrobat Reader
Requires the Registered User plan or above. Login!
-
Top Extension at Stairs: ADA Standard Section 505.10.2
Section 505.10.2 covers the current ADA Standards for the handrail extensions at the top of the stairs.
-
Dishwasher: ADA Standard Section 804.6.3
Clear floor or ground space shall be positioned adjacent to the dishwasher door....
-
Spring Hinges: ADA Standard Section 404.2.8.2
Section 404.2.8.2 covers the current ADA Standards for door and gate spring hinges.
-
11B-404.2.8.2 Spring hinges
Door and gate spring hinges shall be adjusted so that from the open position of 70 degrees, the door or gate shall move to the closed position in 1.5 seconds minimum....
-
11B-804.6.3 Dishwasher
Clear floor or ground space shall be positioned adjacent to the dishwasher door....
-
11B-804.6.3 Dishwasher
Clear floor or ground space shall be positioned adjacent to the dishwasher door....
-
11B-404.2.8.2 Spring hinges
Door and gate spring hinges shall be adjusted so that from the open position of 70 degrees, the door or gate shall move to the closed position in 1.5 seconds minimum....
-
ACCESSIBLE MEANS OF EGRESS
A continuous and unobstructed way of egress travel from any point in a building or facility that provides an accessible route to an area of refuge, a horizontal exit, or a public way....
-
ACCESSIBLE MEANS OF EGRESS
A continuous and unobstructed way of egress travel from any point in a building or facility that provides an accessible route to an area of refuge, a horizontal exit, or a public way....
-
Q: If a PSAP has only received a few TTY calls per month over the past year, why does it need TTYs at every call-taking position?
Q: If a PSAP has only received a few TTY calls per month over the past year, why does it need TTYs at every call-taking position?...
-
Door Closers and Gate Closers: ADA Standard Section 404.2.8.1
Section 404.2.8.1 covers the current ADA Standards for the closing speed of door closers and gate closers.
-
11B-404.2.8.1 Door closers and gate closers
Door closers and gate closers shall be adjusted so that from an open position of 90 degrees, the time required to move the door to a position of 12 degrees from the latch is 5 seconds minimum...
-
11B-404.2.8.1 Door closers and gate closers
Door closers and gate closers shall be adjusted so that from an open position of 90 degrees, the time required to move the door to a position of 12 degrees from the latch is 5 seconds minimum...
-
Load and Unload Areas: ADA Standard Section 206.2.9.1
Section 206.2.9.1 covers scoping requirements in the most current ADA Standards for accessible routes to load and unload areas of amusement rides.
-
11B-206.2.9.1 Load and unload areas
Where load and unload areas have more than one loading or unloading position, at least one loading and unloading position shall be on an accessible route....
