ETA Editor's Note Imposing additional requirements regarding characters and colors, the preceding CBC requirements pertaining to elevator hoistway signs are more stringent...
Search Results "Height Adjustable"
-
11B-407.2.3.2 Reserved
-
11B-407.2.3.2 Reserved
ETA Editor's Note Imposing additional requirements regarding characters and colors, the preceding CBC requirements pertaining to elevator hoistway signs are more stringent...
-
M305.1 General
Supports shall comply with M305.
-
M305.1 General (Section-by-Section Analysis)
This is an introductory section.
-
Accessible Medical Equipment
Importance of Accessible Examination Tables, Chairs and Weight Scales http://www.hfcdihp.org/products Exam Room Selection for Accessible Examination Tables & Chairs PDF...
-
M305.1 General
Supports shall comply with M305, as applicable.
-
11B-604.9 Water closets and toilet compartments for children's use
through 8 Ages 9 through 12 Water Closet Centerline 12 inches (305 mm) 12 to 15 inches (305 to 381 mm) 15 to 18 inches (381 to 457 mm) Toilet Seat Height...
-
11B-604.9 Water closets and toilet compartments for children's use
Water Closet Centerline 12 inches (305 mm) 12 to 15 inches (305 to 381 mm) 15 to 18 inches (381 to 457 mm) Toilet Seat Height...
- Access Board: Tactile Sign Height
-
Drinking Fountains
(This can be accommodated by the use of a "hi-lo" fountain; by providing one fountain accessible to those who use wheelchairs and one fountain at a standard height convenient for those who...
-
602.7 Drinking Fountains for Standing Persons
602.7 Drinking Fountains for Standing Persons. Spout outlets of drinking fountains for standing persons shall be 38 inches (965 mm) minimum and 43 inches (1090 mm) maximum above the...
-
602.6 Water Flow
The spout shall provide a flow of water 4 inches (100 mm) high minimum and shall be located 5 inches (125 mm) maximum from the front of the unit. The angle of the water stream shall...
-
602.7 Drinking Fountains for Standing Persons
Spout outlets of drinking fountains for standing persons shall be 38 inches (965 mm) minimum and 43 inches (1090 mm) maximum above the finish floor or ground.
-
602.7 Drinking Fountains for Standing Persons
Spout outlets of drinking fountains for standing persons shall be 38 inches (965 mm) minimum and 43 inches (1090 mm) maximum above the finish floor or ground.
-
602.6 Water Flow
The spout shall provide a flow of water 4 inches (100 mm) high minimum and shall be located 5 inches (125 mm) maximum from the front of the unit. The angle of the water stream shall...
-
Toilet Rooms North (Celebrity Spies)–Women [sic]
Toilet Rooms North (Celebrity Spies)–Women [sic]: ff. The force required to push or pull open the women's toilet room door is 10 lbf, which exceeds the maximum allowable door...
-
602.6 Water Flow
602.6 Water Flow. The spout shall provide a flow of water 4 inches (100 mm) high minimum and shall be located 5 inches (125 mm) maximum from the front of the unit. The angle of the...
-
11B-602.7 Drinking fountains for standing persons
Spout outlets of drinking fountains for standing persons shall be 38 inches (965 mm) minimum and 43 inches (1092 mm) maximum above the finish floor or ground.
-
11B-602.6 Water flow
The spout shall provide a flow of water 4 inches (102 mm) high minimum and shall be located 5 inches (127 mm) maximum from the front of the unit. The angle of the water stream shall...
-
10.3.1(6)
(6) Lists of stations, routes, or destinations served by the station and located on boarding areas, platforms, or mezzanines shall comply with 4.30.1, 4.30.2, 4.30.3, and 4.30.5. A...
-
4.21.3 Seat
A seat shall be provided in shower stalls 36 in by 36 in (915 mm by 915 mm) and shall be as shown in Fig. 36. The seat shall be mounted 17 in to 19 in (430 mm to 485 mm) from the...
-
4.35.4 Bench
Every accessible dressing room shall have a 24 in by 48 in (610 mm by 1220 mm) bench fixed to the wall along the longer dimension. The bench shall be mounted 17 in to 19 in (430 mm...
-
4.21.3 SEAT
A seat shall be provided in shower stalls 36 in by 36 in (915 mm by 915 mm) and shall be as shown in Fig. 36. The seat shall be mounted 17 in to 19 in (430 mm to 485 mm) from the...
-
11B-602.7 Drinking fountains for standing persons
11B-602.7 Drinking fountains for standing persons. Spout outlets of drinking fountains for standing persons shall be 38 inches (965 mm) minimum and 43 inches (1092 mm) maximum above...