altering a load-bearing member that is an essential part of the structural frame; or because other existing physical or site constraints prohibit modification or addition of elements, spaces...
Search Results "Shower Clear Floor Space"
-
Technically Infeasible
-
B6
Does each accessible parking space have a sign with the symbol of accessibility that is visible when a vehicle is parked in the space? [ADA Standards § 4.6.4] Yes No...
-
A6. ISA Signage
Does each accessible parking space have a sign with the symbol of accessibility that is visible when a vehicle is parked in the space? [ADA Stds 4.6.4] Yes _____ No _____...
-
4.6.4* SIGNAGE
Accessible parking spaces shall be designated as reserved for the disabled by a sign showing the symbol of accessibility (see 4.30.5)....
- Rebuilding Together Saratoga County - Wilton, NY
-
11B-225.2.3 Library book stacks
Book stacks available for public use shall be 54 inches (1372 mm) maximum above the finish floor. Exceptions: 1. ...
-
Who Will Provide the Assistance?
Specific Person(s) in the Office or Building Friend or coworker Relative Supervisor Building staff Floor safety warden...
-
11B-411.2.2.1 Visible identification
The identification fixture shall be 80 inches (2032 mm) minimum above the finish floor or ground to the bottom of the fixture....
-
Fair Labor Standards Act Section 14(c)
At the time, the floor is set at 75 percent of the national minimum wage. In 1966, it is lowered to 50 percent....
-
1.1.16 Alternate measurement tools
Waviness index may be a more appropriate measure to include if floor profilers are used....
-
11B-411.2.2.1 Visible identification
The identification fixture shall be 80 inches (2032 mm) minimum above the finish floor or ground to the bottom of the fixture....
-
§ 38.23(d)(4) Orientation
Additional securement devices or systems shall secure the wheelchair or mobility aid facing forward, or rearward with a padded barrier, extending from a height of 38 inches from the vehicle floor...
-
11B-225.2.3 Library book stacks
Book stacks available for public use shall be 54 inches (1372 mm) maximum above the finish floor. Exceptions: 1. ...
-
11B-411.2.2.1 Visible identification
The identification fixture shall be 80 inches (2032 mm) minimum above the finish floor or ground to the bottom of the fixture....
-
§ 36.406(f)(3)
(3) Facilities that have more than 5,000 seats shall provide at least five wheelchair spaces and at least three companion seats for each wheelchair space; and...
-
Feminine product dispensers
For purposes of resolving this matter, the Museum will provide, on each floor, at least one feminine product dispenser in the women's toilet rooms that does not requires tight grasping and...
-
Volume Controls
Do at least 25% (not less than one) of all other house phones on each floor have volume controls? Yes __ No __ N/A __ Comments: ___________________________________________...
-
Volume Controls
Do at least 25% (not less than one) of all other pay phones on each floor have volume controls? Yes __ No __ N/A __ Comments: ___________________________________________...
-
Volume Controls
Do at least 25% (not less than one) of all other pay phones on each floor have volume controls? Yes __ No __ N/A __ Comments: ___________________________________________...
-
§ 38.31(b)
doorways in which lifts or ramps are installed, shall have, at all times, at least 2 foot-candles of illumination measured on the step tread, or lift or ramp, when deployed at the vehicle floor...
-
11B-809.8.4 Door signal devices
The activating mechanism shall be mounted 48 inches (1219 mm) maximum above the floor and connected to permanent wiring....
-
803.5 Coat Hooks and Shelves
Shelves shall be 40 inches (1015 mm) minimum and 48 inches (1220 mm) maximum above the finish floor or ground....
-
Mary Ann Hay, IALD, LEED™ AP. Artificial Lighting
and have the space feel comfortable....
-
1003.2.13 Accessible means of egress
Accessible spaces shall be provided with not less than one accessible means of egress....