the seat 16 inches (406 mm) minimum and 27 inches (686 mm) maximum from the seat wall; and shall be located above the grab bar, but no higher than 48 inches (1219 mm) above the shower floor...
Search Results "Sign Clear Floor Space"
Commonly Searched Documents
-
11B-608.5.2 Standard roll-in type shower compartments
-
Obstructions [4.7.8]
A landing with a minimum length of 48 inches will provide sufficient turning space....
- Mannington Mills Outlook Collection Commercial Carpet
- Mesa Safe Company MP101 Pedestal Electronic Hotel Safe
-
C. Toilet Rooms:
PSE shall provide and maintain directional signage at inaccessible toilet rooms indicating the location of the nearest accessible toilet room on the Floor Level. ...
-
11B-203.10 Raised refereeing, judging, and scoring areas
An accessible route complying with Division 4 shall be provided to the ground- or floor-level entry points, where provided, of stairs, ladders, or other means of reaching the raised elements...
-
F217.4.1 Bank Requirement
EXCEPTION: TTYs shall not be required at banks of telephones located within 200 feet (61 m) of, and on the same floor as, a bank containing a public TTY....
-
F211.1 General
Where drinking fountains are provided on an exterior site, on a floor, or within a secured area they shall be provided in accordance with F211....
-
217.4.1 Bank Requirement
EXCEPTION: TTYs shall not be required at banks of telephones located within 200 feet (61 m) of, and on the same floor as, a bank containing a public TTY....
-
(5) Reinforced walls for grab bars
The only change made to these guidelines has been to subject powder rooms to the reinforced wall requirement when the powder room is the only toilet facility on the accessible floor of a...
-
I. Security
Is the security latch or bolt on the hall door mounted no higher than 48" above the floor so it is within the reach of persons who use wheelchairs and is it operable with one hand, without...
-
804.3.2 Height
The kitchen work surface shall be 34 inches (865 mm) maximum above the finish floor or ground....
-
§ 38.93(d)(2) Exception
New vehicles operating in existing stations may have a floor height within plus or minus 11/2 inches of the platform height....
-
11B-203.10 Raised refereeing, judging, and scoring areas
An accessible route complying with Division 4 shall be provided to the ground- or floor-level entry points, where provided, of stairs, ladders, or other means of reaching the raised elements...
-
11B-233.3.1.2.1 Elevator buildings
Residential dwelling units on floors served by an elevator shall be adaptable....
-
11B-203.10 Raised refereeing, judging, and scoring areas
An accessible route complying with Division 4 shall be provided to the ground- or floor-level entry points, where provided, of stairs, ladders, or other means of reaching the raised elements...
-
Are redundant controls for an element required to comply?
If redundant controls, other than light switches, serve a single element, one control in each space is not required to comply....
-
2.3
Consent Order after the Effective Date of this Consent Order, these theaters, in each case, shall be in compliance with the requirements of the ADA with respect to (a) providing wheelchair spaces...
-
Accessible Routes
Accessible Routes ADAAG requires that at least one accessible route connect accessible buildings, facilities, elements and spaces on the site....
-
Vertical Clearance [4.6.5]
In garages, at least one vehicular route connecting van spaces to entrances and exits must provide this clearance; van spaces can be clustered on one level....
-
809.2.1 Location
At least one accessible route shall connect all spaces and elements which are a part of the residential dwelling unit....
-
1.2.1
1.2.1 Use the plus - or - minus symbol (±) after a dimension when it must be made clear what the expected tolerance is. This should be coordinated with the specification requirements....
-
Protruding objects and vitrines
aprons, extend bases, or add barriers below objects and vitrines that project more than 4" from walls and have their leading edges greater than 27" and less than 80" above the finished floor...
-
§ 38.107(a)(4)
Controls for flush valves shall be mounted no more than 44 inches above the floor....