We are issuing the final rule pursuant to this authority to establish accessibility guidelines for camping facilities, picnic facilities, viewing areas, trails, and beach access routes constructed...
Search Results "Clear Floor Area"
-
Need for and Objective of Final Rule
-
Elements Not Addressed in Final Rule
The proposed rule included proposed scoping and technical requirements for recreational vehicle parking spaces in general parking areas at camping facilities....
-
Orienting Attendees to the Meeting Space
This may include “big picture” information – the layout of the facility and surrounding area, including landmarks and their relation to each other, for example – or information on a smaller...
-
Location of Accessible Routes
The 2010 Standards require all accessible routes to coincide with or be located in the same general area as general circulation paths....
-
Different "Types"
Different "Types" At least one of each type of play component provided at ground level in a play area must be on the accessible route. ...
-
Symbols of Accessibility [4.30.7]
non-glare finishes system-wide uniformity The International Symbol of Accessibility is used to label accessible: parking spaces check-out aisles [7.3] areas...
-
Egress Signage
Section 216.4 provides specific requirements for means of egress, including exit doors, areas of refuge, and directional signs....
-
E.
Cinemark's auditoria with 300 seats or less, persons who use wheelchairs cannot access the seating on risers as the wheelchair spaces available to them are located on the traditional, sloped-floor...
-
11B-604.8.3 Coat hooks and shelves
Shelves shall be located 40 inches (1016 mm) minimum and 48 inches (1219 mm) maximum above the finish floor. ...
-
11B-307.3.1 Edges and corners
Where signs or other objects are mounted on posts or pylons, and their bottom edges are less than 80 inches (2032 mm) above the floor or ground surface, the edges of such signs and objects...
-
1.9.1.2
with disabilities as follows: Exception: Certain types of privately funded multistory buildings do not require installation of an elevator to provide access above and below the first floor...
-
11B-604.9.5 Flush controls
Hand operated flush controls shall comply with Sections 11B-309.2 and 11B-309.4 and shall be installed 36 inches (914 mm) maximum above the finish floor....
-
608.5.1 Transfer Type Shower Compartments
compartments, the controls, faucets, and shower spray unit shall be installed on the side wall opposite the seat 38 inches (965 mm) minimum and 48 inches (1220 mm) maximum above the shower floor...
-
4.21.6 Shower Unit
EXCEPTION: In unmonitored facilities where vandalism is a consideration, a fixed shower head mounted at 48 in (1220 mm) above the shower floor may be used in lieu of a hand-held shower head...
-
4.21.6 SHOWER UNIT
EXCEPTION: In unmonitored facilities where vandalism is a consideration, a fixed shower head mounted at 48 in (1220 mm) above the shower floor may be used in lieu of a hand-held shower head...
-
11B-604.7.2 Disposal units
The disposal unit shall be located below the grab bar, with the opening of the disposal unit 19” minimum (483 mm) above the finish floor....
-
1.9.1.2 Application
with disabilities as follows: Exception: Certain types of privately funded multistory buildings do not require installation of an elevator to provide access above and below the first floor...
-
§ 38.107(a)(3)
grab bar at least 40 inches long shall be mounted on at least one side wall, with one end not more than 12 inches from the back wall, at a height between 33 inches and 36 inches above the floor...
-
§ 38.123(a)(3)
grab bar at least 40 inches long shall be mounted on at least one side wall, with one end not more than 12 inches from the back wall, at a height between 33 inches and 36 inches above the floor...
-
§ 38.159(c)(3) Ramp threshold
The transition from roadway or sidewalk and the transition from vehicle floor to the ramp may be vertical without edge treatment up to 1/4 inch (6.5 mm)....
-
§ 38.95(c)(3) Ramp threshold
The transition from station platform to the ramp or bridge plate and the transition from car floor to the ramp or bridge plate may be vertical without edge treatment up to 1/4 inch....
-
11B-608.5.1 Transfer type shower compartments
compartments, the controls, faucets, and shower spray unit shall be installed on the side wall opposite the seat 38 inches (965 mm) minimum and 48 inches (1219 mm) maximum above the shower floor...
-
11B-604.9.5 Flush controls
Hand operated flush controls shall comply with Sections 11B-309.2 and 11B-309.4 and shall be installed 36 inches (914 mm) maximum above the finish floor....