For example, awnings and their supporting structures cannot reduce the minimum required vertical clearance....
Search Results "Vertical Clearance"
Commonly Searched Documents
-
11B-307.2 Protrusion limits
-
11B-307.2 Protrusion limits
For example, awnings and their supporting structures cannot reduce the minimum required vertical clearance....
-
Circular Cross Section and Clearance (§505.5, §505.7)
Circular Cross Section and Clearance (§505.5, §505.7)...
-
1010.1.5 Floor elevation
Landings shall be level except for exterior landings, which are permitted to have a slope not to exceed 0.25 unit vertical in 12 units horizontal (2-percent slope)....
- Ascension Virtuoso Portable Wheelchair Lift Demonstration Video
-
307.2 Protrusion Limits
For example, awnings and their supporting structures cannot reduce the minimum required vertical clearance....
-
11B-307.2 Protrusion limits
For example, awnings and their supporting structures cannot reduce the minimum required vertical clearance....
-
307.2 Protrusion Limits
For example, awnings and their supporting structures cannot reduce the minimum required vertical clearance....
-
Clearance in Base (M301.4.1 and M302.4.1)
Clearance in the base of the equipment allows the legs of a portable floor lift to fit under the base of the equipment....
-
11B-809.8.3 Door maneuvering clearance.
At the dwelling unit side of the primary entry doors, secondary exterior doors, and required exit doors maneuvering clearances shall be 44 inches (1118 mm) minimum in length measured...
-
11B-404.2.4.2 Doorways without doors or gates, sliding doors, and folding doors
Doorways less than 36 inches (914 mm) wide without doors or gates, sliding doors, or folding doors shall have maneuvering clearances complying with Table 11B-404.2.4.2....
-
11B-224.8.1 More than 25-bed sleeping rooms
In sleeping rooms with more than 25 beds, a minimum of 5 percent of the beds shall have clear floor space complying with Section 11B-806.2.3.
-
1133A.7 Knee and toe space
1133A.7 Knee and toe space. Knee and toe space, when required by Section 1133A, shall comply with the following:
-
1134A.8, Item 4.3
4.3. Doors to the cabinet beneath the lavatory shall be removable or openable to provide the required unobstructed knee and toe space. The knee and toe space shall be centered...
-
1133A.7, Item 2
2. The knee and toe space shall be 30 inches (762 mm) wide minimum, centered on the sink, countertop or appliance.
-
4.26.2* SIZE AND SPACING OF GRAB BARS AND HANDRAILS
The diameter or width of the gripping surfaces of a handrail or grab bar shall be 1-1/4 in to 1-1/2 in (32 mm to 38 mm), or the shape shall provide an equivalent gripping surface. If...
-
4.26.2* Size and Spacing of Grab Bars and Handrails
The diameter or width of the gripping surfaces of a handrail or grab bar shall be 1‒1/4 in to 1‒1/2 in (32 mm to 38 mm), or the shape shall provide an equivalent gripping surface. If...
-
1134A.8, Item 4.3
4.3. Doors to the cabinet beneath the lavatory shall be removable or openable to provide the required unobstructed knee and toe space. The knee and toe space shall be centered on...
-
1133A.7 Knee and toe space
Knee and toe space, when required by Section 1133A, shall comply with Section 1138A.2 and the following:
-
1133A.7, Item 2
2. The knee and toe space shall be 30 inches (762 mm) wide minimum, centered on the sink, countertop or appliance.
-
1133A.7 Knee and toe space
Knee and toe space, when required by Section 1133A, shall comply with Section 1138A.2 and the following: The knee and toe space shall be clear and unobstructed, or removable...
-
404.2.4.2 Doorways without Doors or Gates
Doorways less than 36 inches (915 mm) wide without doors or gates, sliding doors, or folding doors shall have maneuvering clearances complying with Table 404.2.4.2....
-
404.2.4.2 Doorways without Doors or Gates
Doorways less than 36 inches (915 mm) wide without doors or gates, sliding doors, or folding doors shall have maneuvering clearances complying with Table 404.2.4.2....
-
M301.4.1 Clearance in Base (Section-by-Section Analysis)
Three commenters (two manufacturers and one medical association) raised concerns with the six-inch vertical clearance measured from the floor requirement....