End transfer surfaces shall be 28 inches (710 mm) wide minimum and 17 inches (430 mm) long minimum. ...
Search Results "Transfer Space"
-
M301.2.3.1 End Transfer Surface
-
M301.2.3.2 Side Transfer Surface
Side transfer surfaces shall be 28 inches (710 mm) wide minimum and 28 inches (710 mm) long minimum....
- Autoadapt Turny Evo
-
Spas
Spas Spas must provide at least one accessible means of entry, which can be a pool lift, transfer wall, or transfer system. ...
-
M301.3.1 Transfer Supports (Section-by-Section Analysis)
The MDE NPRM proposed to require transfer supports to be provided for use with transfer sides on diagnostic equipment used by patients in the supine, prone, or side-lying position, and that...
-
11B-809.10.8.2 Floor space
A floor space 30 inches (762 mm) minimum by 48 inches (1219 mm) minimum shall be provided centered on the lavatory....
-
11B-809.10.8.2 Floor space
A floor space 30 inches (762 mm) minimum by 48 inches (1219 mm) minimum shall be provided centered on the lavatory....
-
11B-305.6 Approach
One full unobstructed side of the clear floor or ground space shall adjoin an accessible route or adjoin another clear floor or ground space....
-
11B-305.6 Approach
One full unobstructed side of the clear floor or ground space shall adjoin an accessible route or adjoin another clear floor or ground space....
-
Character Spacing: ADA Standard Section 703.2.7
Character spacing shall be measured between the two closest points of adjacent raised characters within a message, excluding word spaces....
-
4.21.2 SIZE AND CLEARANCES
Shower stall size and clear floor space shall comply with Fig. 35(a) or (b). The shower stall in Fig. 35(a) shall be 36 in by 36 in (915 mm by 915 mm)....
-
4.21.2 Size and Clearances
Except as specified in 9.1.2, shower stall size and clear floor space shall comply with Fig. 35(a) or (b). The shower stall in Fig. 35(a) shall be 36 in by 36 in (915 mm by 915 mm)....
- Access Board: Toilet Rooms
-
Connected Elevated Components
Connected Elevated Components When transfer systems are used, an elevated play component may connect to other elevated play components, providing an innovative, accessible route....
-
304 Turning Space
Objects that provide sufficient knee and toe clearance can overlap a limited portion of the turning space. Comment....
-
Can clear floor/ground space or turning space overlap other space requirements?
Yes, clear floor or ground spaces and turning space can overlap other required clearances, including other clear floor spaces, door maneuvering clearances, and fixture clearances....
-
3.4.4 Clear Ground Space and Turning Space
Each viewing area that is required to be accessible by section 3.4.1 shall have a clear ground or floor space 36 inches (915 mm) minimum by 48 inches (1220 mm) minimum positioned for either...
- Figure 608.2.1 Transfer Type Shower Compartment Size and Clearance – Drawing from the U.S. Access Board
-
Limited Access Spaces (§203.4)
Limited Access Spaces (§203.4) Spaces accessed only by ladders, catwalks, crawl spaces, or very narrow passageways Examples: lighting/ equipment catwalks at stages and performing...
-
R203 Machinery Spaces
R203 Machinery Spaces. Vaults, tunnels, and other spaces used by service personnel only for maintenance, repair, or monitoring are not required to comply with this document....
-
309.2 Clear Floor Space
309.2 Clear Floor Space. A clear floor or ground space complying with 305 shall be provided....
-
5.3 Transfer Sides
5.3 Transfer Sides....
-
4.21.4 Grab Bars
On the one hand, transfers are typically only made into shower chairs outside the shower and with a caregiver’s assistance....
-
Single-User Toilet Rooms: No Side Transfer Space