1.1.15 Flatness of ramp landings. Measure ramp landings at the midpoints of each landing in each direction using a 24 - in (600 mm) digital inclinometer....
Search Results "Ramp Run"
Commonly Searched Documents
-
1.1.15 Flatness of ramp landings
-
§ 38.125(c)(4) Ramp barriers
(4) Ramp barriers. Each side of the ramp or bridge plate shall have barriers at least 2 inches high to prevent mobility aid wheels from slipping off....
-
11B-1008.2.5.3 Handrails
Where required on ramps serving play components, the handrails shall comply with Section 11B-505 except as modified by Section 11B-1008.2.5.3....
-
11B-1008.2.5.3 Handrails
Where required on ramps serving play components, the handrails shall comply with Section 11B-505 except as modified by Section 11B-1008.2.5.3. Exceptions: 1. ...
-
11B-1008.2.5.3 Handrails
Where required on ramps serving play components, the handrails shall comply with Section 11B-505 except as modified by Section 11B-1008.2.5.3. Exceptions: 1....
-
11B-406.5 Common requirements
Curb ramps and blended transitions shall comply with Section 11B-406.5....
-
11B-406.5 Common requirements
Curb ramps and blended transitions shall comply with Section 11B-406.5....
-
11B-406.5 Common requirements
Curb ramps and blended transitions shall comply with Section 11B-406.5....
-
R304.5 Common Requirements
Curb ramps and blended transitions shall comply with R304.5....
-
R409.2 Where Required
Handrails shall be provided on both sides of ramps and stairways....
-
4.8.8 Outdoor Conditions
Outdoor ramps and their approaches shall be designed so that water will not accumulate on walking surfaces....
-
4.8.8 OUTDOOR CONDITIONS
Outdoor ramps and their approaches shall be designed so that water will not accumulate on walking surfaces....
-
Miniature Golf Facilities
Word Fillable Form (1.0MB) Word Non-Fillable Form (1.0MB) PDF Non-Fillable Form (0.5MB)
-
2.4.1.2
A grade of up to 1:12 (8.33 percent) is permitted for up to 50 feet (15 m) of an ORAR. Resting intervals complying with section 2.3 shall be provided at distances of no more than 50...
-
d-ii
Are handrails installed on both sides of each ramp segment? [ADA Standards § 4.8.5] Yes No...
-
f-ii
Are handrails installed on both sides of each ramp segment? [ADA Standards § 4.8.5] Yes No...
-
4b.
Is the ramp width, measured between handrails, at least 36 inches? [ADA Stds 4.8.3] Yes _____ No _____...
-
d-iii
Is the ramp width, measured between handrails, at least 36 inches? [ADA Standards § 4.8.3] Yes No...
-
C1-e
Where an accessible route crosses a curb, is a curb ramp provided? [ADA Standards § 4.3.8] Yes No...
-
f-iii
Is the ramp width, measured between the handrails, at least 36 inches? [ADA Standards § 4.8.3] Yes No...
-
Wet Conditions [§405.10]
Wet Conditions [§405.10] Landings subject to wet conditions must be designed to prevent the accumulation of water. Landings are permitted slopes not steeper than 1:48 to allow for...
-
1007.2, Item 8
Ramps complying with Section 1010, and Chapter 11A, Sections 1114A and 1122A, or Chapter 11B, 11B-405, as applicable....
-
1009.2, Item 8
Ramps complying with Section 1012, and Chapter 11A, Sections 1114A and 1122A, or Chapter 11B, 11B-405, as applicable....
-
4f.
Is a level landing, at least 60 inches by 60 inches, provided where a ramp changes direction? [ADA Stds 4.8.4] Yes _____ No _____...