Features Fixed or pit-mounted ramp provides easy entry when lift is lowered and additional stability when lift is raised Constant pressure paddle switch with emergency stop...
Search Results "Raised Key"
- Harmar EPL Enclosed Vertical Platform Lift
-
Summary of significant issues raised by public comments in response to the NPRM Paperwork Reduction Act analysis and annual reporting burden estimate
Summary of significant issues raised by public comments in response to the NPRM Paperwork Reduction Act analysis and annual reporting burden estimate. Comment....
-
407.6 Status Indicators
Status indicators, including all locking or toggle controls or keys (e.g., Caps Lock and Num Lock keys), shall be discernible visually and by touch or sound....
-
PLATFORM
A raised area within a building used for worship, the presentation of music, plays or other entertainment; the head table for special guests; the raised area for lecturers and speakers;...
-
PLATFORM
A raised area within a building used for worship, the presentation of music, plays or other entertainment; the head table for special guests; the raised area for lecturers and speakers;...
-
§ 1194.23(k)(3)
(3) If key repeat is supported, the delay before repeat shall be adjustable to at least 2 seconds. Key repeat rate shall be adjustable to 2 seconds per character....
-
11B-411.2.1.4.1.1 Arrangement
Buttons shall be arranged in columns to the right of the keypad with a minimum horizontal spacing of 1.5 times the horizontal spacing between the numeric keys and with the same vertical...
-
11B-411.2.1.4.1.1 Arrangement
Buttons shall be arranged in columns to the right of the keypad with a minimum horizontal spacing of 1.5 times the horizontal spacing between the numeric keys and with the same vertical...
-
11B-411.2.1.4.1.1 Arrangement
Buttons shall be arranged in columns to the right of the keypad with a minimum horizontal spacing of 1.5 times the horizontal spacing between the numeric keys and with the same vertical...
-
§382.57(c)(3)(iii) Status indicators
Status indicators, including all locking or toggle controls or keys (e.g., Caps Lock and Num Lock keys), must be discernible visually and by touch or sound; and...
-
§27.71(k)(3)(iii) Status Indicators.
Status indicators, including all locking or toggle controls or keys (e.g., Caps Lock and Num Lock keys), must be discernible visually and by touch or sound; and...
-
§ 382.57(c)(3)(iii) Status indicators
Status indicators, including all locking or toggle controls or keys (e.g., Caps Lock and Num Lock keys), must be discernible visually and by touch or sound; and...
-
§ 27.71(k)(3)(iii) Status indicators
Status indicators, including all locking or toggle controls or keys (e.g., Caps Lock and Num Lock keys), must be discernible visually and by touch or sound; and...
-
§ 37.51(d)(3)
(3) The commuter authority and responsible person(s) of each key station identified in the plan shall, by mutual agreement, designate a project manager for the purpose of undertaking the...
-
TACTILE SIGN
[DSA-AC] A sign containing raised characters and/or symbols and accompanying Braille....
-
TACTILE SIGN
[DSA-AC] A sign containing raised characters and/or symbols and accompanying Braille....
-
§ 1194.23(k)(2)
(2) Controls and keys shall be operable with one hand and shall not require tight grasping, pinching, or twisting of the wrist. ...
-
Question 18
Or, if keys are required for all facilities, are the keys for the accessible facilities available in an accessible location?...
-
11B-1009.2.6 Footrests and armrests
The armrest positioned opposite the water shall be removable or shall fold clear of the seat when the seat is in the raised (load) position....
-
11B-1009.2.6 Footrests and armrests
The armrest positioned opposite the water shall be removable or shall fold clear of the seat when the seat is in the raised (load) position....
-
Car Controls: ADA Standard Section 409.4.6
Section 409.4.6 covers the current ADA Standards for the car controls in private residence elevators.
-
Position: ADA Standard Section 703.3.2
Braille shall be separated 3/8 inch (9.5 mm) minimum from any other tactile characters and 3/8 inch (9.5 mm) minimum from raised borders and decorative elements....
-
11B-703.3.2 Position
Braille shall be separated 3/8 inch (9.5 mm) minimum and ½ inch (12.7 mm) maximum from any other tactile characters and 3/8 inch (9.5 mm) minimum from raised borders and decorative elements...
-
11B-703.3.2 Position
Braille shall be separated 3/8 inch (9.5 mm) minimum and ½ inch (12.7 mm) maximum from any other tactile characters and 3/8 inch (9.5 mm) minimum from raised borders and decorative elements...