counters and work surfaces shall be accessible, including: patient wardrobes, nurse’s stations, administrative centers, reception desks, medicine preparation areas, laboratory work stations, equipment...
Search Results "Exercise Equipment"
-
11B-805.7 Built-in cabinets and work surfaces
-
Exercise machines. (Section-by-Section Analysis)
Sections 206.2.13 and 236 of the 2004 ADAAG require one of each type of fixed exercise machine to meet clear floor space specifications and to be on an accessible route. ...
-
5.2.1.3 Transfer Surface Size Recommendations for Stretchers (M301)
The point of entry to the equipment is in the center. The length of the stretcher means a patient would transfer on in the middle....
-
5.8.2.4 Unobstructed Floor Space Recommendation
Rationale for the recommendation The overall knee and toe clearance and unobstructed floor space dimensions dictate how close a patient in a wheelchair can get to the mammography equipment...
-
5.8.2.7 Base Support Allowance Recommendation
It does obstruct the floor space in front of the gantry and, thus, may limit how close a wheelchair can get to the equipment....
-
M303.2.5 Surfaces (Section-by-Section Analysis)
The MDE NPRM proposed to require diagnostic equipment used by patients seated in a wheelchair to provide a wheelchair space with a surface that does not slope more than 1:48 in any direction...
-
5.6.1 Stirrups Provision for M301
The Committee recommends where equipment provides stirrups, it must also provide an alternate method to support, position, and secure the patient’s legs (specifically including sufficient...
-
M303.3 Entry
Where there is a change in level at the entry to wheelchair spaces, the change in level shall comply with M303.3.
-
M305.3.2 Height
The height of gripping surfaces for standing supports shall be based on the position of the standing supports in relation to the standing surfaces they serve. Horizontal standing...
-
M303.2.4.2.1 Depth
Wheelchair spaces shall include knee and toe clearance 17 inches (430 mm) deep minimum and 25 inches (635 mm) deep maximum.
-
M305.3.2 Height (Section-by-Section Analysis)
For horizontal supports, the MDE NPRM proposed a gripping surface height of 34 inches minimum and 38 inches maximum above the standing surface. There were no public comments on this...
-
§ 1194.23(k)
(k) Products which have mechanically operated controls or keys, shall comply with the following:
-
M303.3 Entry (Section-by-Section Analysis)
This is an introductory section.
-
5.8.1 Wheelchair Spaces on Raised Platforms
5.8.1 Wheelchair Spaces on Raised Platforms.
-
M303.3 Entry
Where there is a change in level at the entry to a wheelchair space, the change in level shall comply with M303.3.
- IDeA Center: Transferring from Wheeled Mobility to MidMark's Barrier-Free Examining Table
-
M303.3.3 Ramped (Section-by-Section Analysis)
The MDE NPRM proposed that for equipment with a change in level at the entry of a wheelchair space, level changes greater than ½ inch high would be required to be ramped and comply with...
-
Healthcare Stories - Alice Wong
Requires the Registered User plan or above. Login!
-
DREDF: Part 1 Barriers to Healthcare-Tables and Scales
Requires the Registered User plan or above. Login!
-
M305 Supports
[See subsections ...]
-
M305 Supports
[See subsections ...]
-
(3) Adjustability: Transfer Surface Intermediate Heights
Under the proposed rule, diagnostic equipment would be in compliance if it provided a low transfer height anywhere within the range of 17 inches minimum and 19 inches maximum....
-
2. Standing Supports
The Access Board received two comments, one of which addressed standing supports on mammography equipment (discussed above in Section IV.D.1 (Significant Changes – Standing Supports)) and...
- American National Standard/AAMI HE75:2009/(R)2013 Human factors engineering – Design of medical devices