Search Results "Emergency Warning System"
Commonly Searched Documents
- ADA Solutions, Inc. Surface Applied Detectable Warning System Truncated Dome Detectable Warning Systems; Part 3660IDRET1
-
ADA Solutions, Inc. Surface Applied Detectable Warning System Truncated Dome Detectable Warning Systems; Part 3648IDRET2
Requires the Premium User plan or above. (Login or upgrade your account!)
-
11B-406.6 Islands
Islands shall have detectable warnings complying with Section 11B-705. FIGURE 11B-406.6 ‡‡ ISLANDS IN CROSSINGS...
- Hearing Loop Systems Demo Video
-
106.5.11 Assistive Listening System (ALS)
An amplification system utilizing transmitters, receivers, and coupling devices to bypass the acoustical space between a sound source and a listener by means of induction loop, radio frequency...
-
4.34.2(10)
(10) Emergency alarms as required by 4.1 and complying with 4.28.4 shall be provided in the dwelling unit....
-
11B-215 Fire alarm systems and carbon monoxide alarm systems
[2010 ADA Standards] 215 Fire Alarm Systems ETA Editor’s Note The CBC includes carbon monoxide alarm systems. Therefore, the CBC is more inclusive....
-
1009.8.2 Directions
Directions for the use of the two-way communication system, instructions for summoning assistance via the two-way communication system and written identification of the location shall be...
-
2. BACKGROUND
BACKGROUND Three types of ALS are in widespread use at the present time: Induction Loop (IL) systems, Frequency Modulated (FM) radio systems, and Infrared (IR) systems....
-
SECTION 907 FIRE ALARM AND DETECTION SYSTEMS
[See subsections ...]
-
SECTION 907 FIRE ALARM AND DETECTION SYSTEMS
[See subsections ...]
-
e-ii
e-ii. Does the floor area of the elevator car have space to enter, reach the controls, and exit? [ADA Standards § 4.10.9, Fig. 22] Yes No Note: See Figure 22 for...
-
B. Parking
B. Parking
-
E1-e
E1-e. Is an elevator provided to each of the levels on which each sheltering service or activity area is located? Yes No
-
I1
I1. If at least one public telephone or one bank of telephones is provided, does at least one of each type of telephone (e.g., pay telephone, intercom telephone, other telephone)...
-
M21
M21. If a coat hook is provided, is it mounted no higher than 54 inches above the floor for a side approach or 48 inches above the floor for a front approach? [ADA Standards §...
-
M5
M5. If there is a raised threshold, is it no higher than 3/4 inch at the door and beveled on both sides? [ADA Standards §§ 4.1.6(3)(d)(ii); 4.13.8] Yes No If No,...
-
H11
H11. If mirrors are provided, is the bottom of the reflecting surface for the mirror at this lavatory no higher than 40 inches above the floor or is a full length mirror provided?...
-
M12
M12. If a mirror is provided, is the bottom of the reflecting surface no higher than 40 inches above the floor or is a full length mirror provided? [ADA Standards...
-
I. Public Telephones
I. Public Telephones When public telephones are provided, then one or more accessible public telephones should be provided in areas serving shelter activity and service areas....
-
1. Typical Issues for Individuals Who Use Wheelchairs, Scooters, or Other Mobility Devices
1. Typical Issues for Individuals Who Use Wheelchairs, Scooters, or Other Mobility Devices The interior accessible route connects the accessible entrance with the various service...
-
E. Hallways and Corridors
E. Hallways and Corridors
-
11B-219 Assistive listening systems
[See subsections ...]
-
R305.1.1 Dome Size
R305.1.1 Dome Size. The truncated domes shall have a base diameter of 23 mm (0.9 in) minimum and 36 mm (1.4 in) maximum, a top diameter of 50 percent of the base diameter minimum and...