H18. Is the centerline of the toilet 18 inches from the adjacent side wall? [ADA Standards § 4.16.2; 4.17.3] Yes No
Search Results "Emergency Service"
-
H18
-
A6
A6. If a curb ramp is provided, is the running slope of the ramp surface (not counting the side flares) no more than 1:12 or 8.33% [ADA Standards § 4.7.2] Yes No
-
M11
M11. Does that lavatory have controls that operate easily with one hand, without tight grasping, pinching, or twisting of the wrist? [ADA Standards § 4.19.5] Yes No
-
D5
D5. If there is a raised threshold, is it no higher than 3/4 inch at the door and beveled on both sides? [ADA Standards §§ 4.1.6(3)(d)(ii), 4.13.8] Yes No If No,...
-
e-iv
e-iv. Are the highest floor control buttons mounted no more than 54 inches above the floor for a side reach or 48 inches for forward reach? [ADA Standards § 4.10.12...
-
I2
I2. Does the phone have volume controls? [ADA Standards § 4.31.5] Yes No
-
g-i
g-i. Is the clear width for the door opening at least 32 inches measured when the door is open 90 degrees? [ADA Standards §§ 4.1.3(7), 4.13.5] Yes No
-
H19
H19. Is the top of the toilet seat 17 inches to 19 inches above the floor? [ADA Standards § 4.16.3] Yes No
-
I3
I3. If three or more telephones are located in one bank serving the shelter, are a shelf and an electrical outlet provided at one telephone for use of a portable TTY? [ADA Standards...
-
M16
M16. Is the centerline of the toilet 18 inches from the adjacent side wall? [ADA Standards §§ 4.16.2; 4.17.3] Yes No
-
H28
H28. Is the surface of the toilet seat in this 36-inch-wide stall 17 to 19 inches above the floor? [ADA Standards §§ 4.16.3; 4.22.4] Yes No
-
M17
M17. Is the top of the toilet seat 17 to 19 inches above the floor? [ADA Standards § 4.16.3] Yes No
-
A7
A7. Is the width of the curb ramp surface at least 36 inches (not counting the side flares)? [ADA Standards § 4.7.3] Yes No
-
e-ii
e-ii. Is the running slope (up or down the ramp) no more than 1:12? [ADA Standards § 4.7.2] Yes No Note: 1:12 is one inch of vertical height for 12 inches of...
-
f-viii
f-viii. If the ramp or landing has a vertical drop-off on either side, is edge protection provided? [ADA Standards § 4.8.7] Yes No
-
B7-b
B7-b. Is the slope (up or down the ramp) no more than 1:12? [ADA Standards § 4.7.2] Yes No Note: 1:12 is one inch of vertical height for each 12 inches of length.
-
e-i
e-i. Is the curb ramp surface at least 36 inches wide, excluding flared sides? [ADA Standards § 4.7.3] Yes No
-
c-i
c-i. If Yes, is a ramp or sloped hallway provided? Yes No If Yes, go to question E1-d.
-
B7-a
B7-a. Is the curb ramp surface at least 36 inches wide, excluding flared sides? [ADA Standards § 4.7.3] Yes No
-
Sec. 225. Telecommunications services for hearing-impaired and speech-impaired individuals [Section 401] [Title IV] [47 U.S.C. § 225]
[See subsections ...]
-
Personal Devices and Services
Public entities are not required to provide personal devices such as wheelchairs and walkers or services such as assistance eating, toileting or dressing....
-
Directions to and through the Usable Circulation Path
Because this technology is new to the market, such devices and systems are not discussed here; however, emergency evacuation personnel and people with disabilities may want to investigate...
-
A. Accessible Entrance
Accessible Entrance Having a way to get into the emergency shelter on a surface that is firm, stable, slip resistant, without steps or steep slopes, and wide enough for a person using...
-
Do companies need to review all their products and services for accessibility and usability?
Do companies need to review all their products and services for accessibility and usability? Yes. Accessibility and usability must be assessed for individual products and services....