If seating for people in wheelchairs is provided at tables or counters, knee spaces at least 27 in (685 mm) high, 30 in (760 mm) wide, and 19 in (485 mm) deep shall be provided (see Fig....
Search Results "Counter Length"
Commonly Searched Documents
-
4.32.3 Knee Clearances
-
ADAPTABILITY
The ability of certain building spaces and elements, such as kitchen counters, sinks, and grab bars, to be added or altered so as to accommodate the needs of either disabled or nondisabled...
-
4.34.6.1* CLEARANCE
Clearances between all opposing base cabinets, counter tops, appliances, or walls shall be 40 in (1015 mm) minimum, except in U-shaped kitchens, where such clearance shall be 60 in (1525...
-
Knee and Toe Space
If the forward reach to operable parts extends over an obstruction, such as a counter, clearances for toes and knees is required below....
-
804.2.2 U-Shaped
In U-shaped kitchens enclosed on three contiguous sides, clearance between all opposing base cabinets, counter tops, appliances, or walls within kitchen work areas shall be 60 inches (1525...
-
11B-804.2.2 U-Shaped
In U-shaped kitchens enclosed on three contiguous sides, clearance between all opposing base cabinets, counter tops, appliances, or walls within kitchen work areas shall be 60 inches (1524...
-
227 Sales and Service
Section 227 covers access to check-out aisles (227.2), sales and service counters (227.3), food service lines (227.4), and queues and waiting lines (227.5)....
-
11B-704.2.1.2 Forward approach
Where a forward approach is provided at a telephone within an enclosure, the counter may extend beyond the face of the telephone 20 inches (508 mm) into the required clear floor or ground...
-
Example: One Step Entry Police Station
After review of the programs and services provided at the station, the town determines that the public entrance, lobby, and service counter need to be accessible to provide program accessibility...
-
11B-704.2.1.2 Forward approach
Where a forward approach is provided at a telephone within an enclosure, the counter may extend beyond the face of the telephone 20 inches (508 mm) into the required clear floor or ground...
-
Standing Supports (M304.3 and M305.3)
Standing Supports (scales serving both wheelchair and standing users) • Sub-Committee Recommendation: Standing Supports - Length The length of the standing supports to be 32” minimum...
-
Running Slope [1017.7.1]
Trails or trail segments of any length may be constructed with running slopes up to 1:20 (5 percent)....
-
Landings: ADA Standard Section 406.4
Section 406.4 covers the current ADA Standards for curb ramp landings.
-
4.32.3 KNEE CLEARANCES
If seating for people in wheelchairs is provided at tables, counters, and work surfaces, knee spaces at least 27 in (685 mm) high, 30 in (760 mm) wide, and 19 in (485 mm) deep shall be provided...
-
221.2.3.1 Horizontal Dispersion
shall not be required in assembly areas with 300 or fewer seats if the companion seats required by 221.3 and wheelchair spaces are located within the 2nd or 3rd quartile of the total row length...
-
Running Slope [1018.7.1]
When the running slope of a segment of beach access route is steeper than 1:20 (5 percent), the maximum length of the segment is specified in table 6, and a resting interval must be provided...
-
221.2.3.1 Horizontal Dispersion
shall not be required in assembly areas with 300 or fewer seats if the companion seats required by 221.3 and wheelchair spaces are located within the 2nd or 3rd quartile of the total row length...
-
505.6 Gripping Surface
Handrail gripping surfaces shall be continuous along their length and shall not be obstructed along their tops or sides....
-
11B-809.8.3 Door maneuvering clearance.
At the dwelling unit side of the primary entry doors, secondary exterior doors, and required exit doors maneuvering clearances shall be 44 inches (1118 mm) minimum in length measured...
-
Kitchens and Kitchenettes
Section 4.34.6 requires a clearance between opposing base cabinets, counters, appliances, or walls of at least 40 inches except in a U-shaped kitchen where the minimum clearance is 60 inches...
-
704.2.1.2 Forward Approach
Where a forward approach is provided, the distance from the front edge of a counter within the telephone enclosure to the face of the telephone unit shall be 20 inches (510 mm) maximum....
-
4.7.9.3 Height
The counter or rim of the sink shall be no more than 34 inches (865 mm) above the floor or ground....
-
2. Standing Supports
(at least 80 percent of the platform length) at the platform entry edge....
-
4.2 Clear Floor Area
Clear Floor Area (Occupied) Length for All Devices Recent revisions to standards in Australia and the U.K. have increased the clear floor area dimensions in both width and length...