Flush controls shall be located on the open side of the water closet except in ambulatory accessible compartments complying with Section 11B-604.8.2....
Search Results "Closet"
-
11B-604.6 Flush controls
-
604.1 General
Water closets and toilet compartments shall comply with 604.2 through 604.8....
-
604.1 General
Water closets and toilet compartments shall comply with 604.2 through 604.8....
-
604.1 General
Water closets and toilet compartments shall comply with 604.2 through 604.8....
-
4.34.5.2(1)
(1) Clear floor space at the water closet shall be as shown in Fig. 47(a). The water closet may be located with the clear area at either the right or left side of the toilet....
-
604.1 General
Water closets and toilet compartments shall comply with 604.2 through 604.8....
-
Rear Grab Bar
The proposed rule specified that the rear grab bar be 24 inches long minimum, centered on the water closet, or at least 36 inches long "where wall space permits" (604.5.2)....
-
California: Toilet Grab Bars - Uneven height allowed?
Grab bars for water closets shall comply with Section 11B-609. Grab bars shall be provided on the side wall closest to the water closet and on the rear wall....
-
1134A.6, Item 1.2
A water closet may project a maximum of 12 inches (305 mm) into the opening provided that a minimum of 36 inches (914 mm) clear space is maintained between the water closet and the shower...
-
Toilet and Bathing Facilities: ADA Standard Section 807.2.4
Where provided, no fewer than one water closet, one lavatory, and one bathtub or shower shall comply with the applicable requirements of 603 through 610....
-
11B-604.1 General
Water closets and toilet compartments shall comply with Sections 11B-604.2 through 11B-604.8....
-
11B-604.1 General
Water closets and toilet compartments shall comply with Sections 11B-604.2 through 11B-604.8....
-
1115B.4.1, Item 1
When 2013 CBC was drafted, the location of accessible water closets was more narrowly restricted, but for water closets permitted and/or installed between August 1, 2012 and January 1, 2014...
-
Flush Controls
The original ADAAG specified that the controls be located on the wide side of the water closet....
-
11B-604.1 General
Water closets and toilet compartments shall comply with Sections 11B-604.2 through 11B-604.8....
- Illinois Valley Center for Independent Living (IVCIL) - LaSalle, IL
-
Unisex Toilet Rooms
., two water closets, or one water closet and one urinal). This differs from the proposed rule which required unisex toilet rooms to have one water closet....
-
11B-604.7.1 Dispensers
Toilet paper dispensers shall comply with Section 11B-309.4 and shall be 7 inches (178 mm) minimum and 9 inches (229 mm) maximum in front of the water closet measured to the centerline of...
-
11B-807.2.4 Toilet and bathing facilities
Where provided, no fewer than one water closet, one lavatory, and one bathtub or shower shall comply with the applicable requirements of Sections 11B-603 through 11B-610....
-
11B-807.2.4 Toilet and bathing facilities
Where provided, no fewer than one water closet, one lavatory, and one bathtub or shower shall comply with the applicable requirements of Sections 11B-603 through 11B-610....
-
11B-604.7.1 Dispensers
Toilet paper dispensers shall comply with Section 11B-309.4 and shall be 7 inches (178 mm) minimum and 9 inches (229 mm) maximum in front of the water closet measured to the centerline of...
-
11B-604.8.1.1.3 Maneuvering space with end-opening door
In a wheelchair accessible compartment with a door located in the front wall or partition (facing the water closet), either in-swinging or out-swinging, a minimum 60 inches (1524 mm) wide...
-
SETTLEMENT AGREEMENT BETWEEN THE UNITED STATES OF AMERICA AND PALACE SPORTS AND ENTERTAINMENT, LLC, REGARDING THE PALACE OF AUBURN HILLS
[See subsections ...]
-
604.8.1.1 Size
Wheelchair accessible compartments shall be 60 inches (1525 mm) wide minimum measured perpendicular to the side wall, and 56 inches (1420 mm) deep minimum for wall hung water closets and...