Search Results "Ceiling Mounted Patient Lift"
- Brewer Access™ High-Low Exam Table
-
M302.1 General
Where diagnostic equipment is used by patients in a seated position, it shall comply with M302....
-
206.7.3 Incidental Spaces
Platform lifts shall be permitted to provide an accessible route to incidental spaces which are not public use spaces and which are occupied by five persons maximum....
-
c. Transfer Surface Size for Diagnostic Equipment Used by Patients in the Supine, Prone, or Side-lying Position
Those advocating for a larger width were concerned about the ability of the patient to reposition after transfer and about accommodating obese patients....
-
M305.2.2 Length (Section-by-Section Analysis)
The Committee explained that the transfer support length provides the gripping surface for the patient to grasp or maintain balance while transferring....
-
Breast Platform [M303.4.1]
Another member emphasized the importance of considering patients of short stature in addition to considering patients seated in a wheelchair....
-
§ 38.23(b)(12) Use by standees
Lifts shall accommodate persons using walkers, crutches, canes or braces or who otherwise have difficulty using steps....
-
11B-213.2.2 Unisex (Patient) toilet rooms in medical care and long-term care facilities
Common-use unisex toilet rooms for exclusive patient use not located within patient bedrooms shall contain a lavatory and one water closet....
-
11B-213.2.2 Unisex (Patient) toilet rooms in medical care and long-term care facilities
Common-use unisex toilet rooms for exclusive patient use not located within patient bedrooms shall contain a lavatory and one water closet....
-
Guest Rooms and Residential Dwelling Units: ADA Standard Section 206.7.6
Section 206.7.6 covers scoping requirements in the most current ADA Standards for accessible routes connecting to mobility features in guest rooms and residential dwelling units.
-
M305.2.5 Surface Hazards (Section-by-Section Analysis)
were submitted on this issue, but the MDE Advisory Committee voiced concern about surface hazards stating, “gripping surface configurations must provide an effective and safe surface for patients...
-
§ 38.95(b)(3) Emergency operation
The lift shall incorporate an emergency method of deploying, lowering to ground or platform level with a lift occupant, and raising and stowing the empty lift if the power to the lift fails...
-
5.4.4 Transfer Support Distance from Transfer Surface Recommendations for M301 and M302
Discussion: The Access Board is considering whether the following technical criteria would be appropriate for the location and size of transfer supports on diagnostic equipment used by patients...
-
Figure M3: Overview of M302 Diagnostic Equipment for Use by a Patient in a Seated Position
[See subsections ...]
-
11B-1009.2.7 Operation
The lift shall be capable of unassisted operation from both the deck and water levels....
-
11B-1009.2.7 Operation
The lift shall be capable of unassisted operation from both the deck and water levels....
-
11B-805.2 Patient bedrooms and resident sleeping rooms
Patient bedrooms and resident sleeping rooms required to provide mobility features shall comply with Section 11B-805.2....
-
11B-805.2 Patient bedrooms and resident sleeping rooms
Patient bedrooms and resident sleeping rooms required to provide mobility features shall comply with Section 11B-805.2....
-
11B-805.2 Patient bedrooms and resident sleeping rooms
Patient bedrooms and resident sleeping rooms required to provide mobility features shall comply with Section 11B-805.2....
-
F223.2.1 Facilities Not Specializing in Treating Conditions That Affect Mobility
In facilities not specializing in treating conditions that affect mobility, at least 10 percent, but no fewer than one, of the patient sleeping rooms shall provide mobility features complying...
-
11B-1009.2.7 Operation
The lift shall be capable of unassisted operation from both the deck and water levels....
-
5.1 Transfer Surface Height Recommendations
This height is also critical for patients who use mobility aids such as walkers and canes and may find it difficult to get up onto or down from an examination chair or table or imaging bed...
-
5.4.8 Transfer Support Gripping Surface Hazard Recommendation for M301 and M302
Rationale for the recommendation Gripping surface configurations must provide an effective and safe surface for patients to hold onto....
-
1009.2.7 Operation
The lift shall be capable of unassisted operation from both the deck and water levels....