Swimming Pool Entrance and Deck (1) Defendants will install a self-operated pool lift complying with 2010 ADA Standards §§ 242.2 and 1009.2 at the main swimming pool....
Search Results "Ceiling Mounted Patient Lift"
-
F. Swimming Pool Entrance and Deck
-
6.1(4)(a)
of the patient bedrooms that are being added or altered shall comply with 6.3....
-
M305.4 Leg Supports
Leg supports shall provide a method of supporting, positioning, and securing the patient’s legs....
-
1009.2.8 Submerged Depth
The lift shall be designed so that the seat will submerge to a water depth of 18 inches (455 mm) minimum below the stationary water level....
-
11B-1009.2.8 Submerged depth
The lift shall be designed so that the seat will submerge to a water depth of 18 inches (457 mm) minimum below the stationary water level....
-
§ 38.83(b)(12) Use by standees
Lifts shall accommodate persons using walkers, crutches, canes or braces or who otherwise have difficulty using steps....
-
1009.2.8 Submerged Depth
The lift shall be designed so that the seat will submerge to a water depth of 18 inches (455 mm) minimum below the stationary water level....
- Ranger Pool Lift Anchor Installation (Core-drill, Retro-fit) Video Instructions
-
i. Medical examination and treatment tables and chairs
i. Medical examination and treatment tables and chairs Healthcare providers use examination and treatment tables and chairs for many different types of medical and dental...
-
M305.2.6 Gripping Surfaces (Section-by-Section Analysis)
The MDE Advisory Committee explained that: [t]ransfer supports may contain elements to provide structural support or prevent patient entrapment....
-
Maintenance of Accessible Features
For example, a portable pool lift may be stored when the pool is closed but it must be at poolside and fully operational during all open pool hours....
- Corbin Russwin Inc. BLSS Trim Lever Handle & Lockset
-
17 Inch Low Height
A 17 inch height allows for safer, easier transfers of patients whose wheelchair height is at the low end of those ranges....
-
General: ADA Standard Section 805.1
Medical care facility and long-term care facility patient or resident sleeping rooms required to provide mobility features shall comply with 805....
-
11B-206.7.9 Team or player seating
Platform lifts shall be permitted to provide accessible routes to team or player seating areas serving areas of sport activity. [2010 ADAS] Advisory 206.7.9 Team or Player Seating....
-
5.2.1.1 Transfer Surface Width
The transfer surface should be 28 inches wide minimum for equipment used by patients in a supine, side-lying, or prone position....
-
5.4.7 Transfer Support Gripping Surface Clearance Recommendation for M301 and M302
Preamble Discussion: The Access Board is considering whether 1½ inches minimum clearance around the gripping surface would be appropriate for transfer supports on diagnostic equipment used by patients...
-
§ 38.125(b)(10) Platform movement
No part of the platform shall move at a rate exceeding 6 inches/second during lowering and lifting an occupant, and shall not exceed 12 inches/second during deploying or stowing....
-
5.2.1 Transfer Surface Size Recommendations for M301
5.2.1 Transfer Surface Size Recommendations for M301 Description: The transfer surface is the part of the diagnostic equipment onto which patients who use mobility devices or aids transfer...
-
Title III Readily Achievable Barrier Removal
If installation of a fixed lift is not readily achievable, the public accommodation may then consider alternatives such as use of a portable pool lift that complies with the 2010 Standards...
-
307 Protruding Objects
Objects mounted on walls and posts can be hazardous to persons with vision impairments unless treated according to the specifications in section 307 for protruding objects....
-
5.2.1.2 Transfer Surface Depth
The transfer surface should be 17 inches deep minimum for all equipment used by patients in a supine, side-lying, or prone position with the exception of imaging equipment....
-
§ 38.159(b)(10) Platform movement
No part of the platform shall move at a rate exceeding 6 inches/second (150 mm/sec) during lowering and lifting an occupant, and shall not exceed 12 inches/second (300 mm/sec) during deploying...
-
5.4.2.1 Transfer Support Length for Stretchers
5.4.2.1 Transfer Support Length for Stretchers. Transfer supports on stretchers should be a minimum of 15 inches long.